Page 7
2. To be certain that the pool or spa’s electrical system meets all applicable requirements, the electrician
should also consult the local building department.
3. Use only approved wet niches (see following note) to ensure a safe and proper installation.
NOTE
Jandy Pool and Spa Lights are ETL listed (ETL
report/file 3033587.001)
for installation with
only
the following
manufacturer’s wet niche fixtures:
Large / Pool Type Niche Model Numbers:
Pentair: 7821XXXX, 7822XXXX, 7823XXXX, 792067XX, 792089XX
Hayward DuraNiche: SP0600U
Sta-Rite: 05161-XXXX, 05163-XXXX
Small / Spa Type Niche Model Numbers:
Pentair: 7824XXXX, 792066XX
Hayward DuraNiche: SP0601U
Sta-Rite: 05166-XXXX, 05167-XXXX
3.2
Installing the Light Fixture
NOTE
Perform these steps
only
after the electrical system requirements are met.
1. Feed cord through conduit to Junction Box, leaving at least four (4) feet of cord at the light
fi
xture
to coil around the light; see Figure 1 (or Figure 2, for spa). This four (4) feet of cord around the light
allows the light to be serviced after the pool or spa is
fi
lled with water.
2. Cut the cord at the Junction Box, leaving at least six (6) inches of cord to make connections.
3. Strip six (6) inches of the outer cord jacket to expose the three insulated wires.
Be careful not to
damage the insulation on the three (3) inner wires
.
4. Install strain relief over cord jacket and connect all three (3) wires to the corresponding circuit wires in
the Junction Box. Install the Junction Box cover.
Figure 2. Jandy Digital Spa Light
WARNING
Never operate this underwater light for more than 10 seconds unless it is totally submerged in water.
Without total submersion, the light assembly will get extremely hot, which may result in serious burns
or in breakage of the bulb or lens. This may result in serious injury to pool or spa users, installers, or
bystanders or in damage to property.
4" min.
48"
min.
8" min. Junction Box or
Low Voltage Transformer.
18" min. to top of Lens.
6.0"
Concrete must be cut
back around Niche to
allow for a compacted
plaster seal.
Coil 4 ft. of light cable
around Fixture.
#8 AWG Ground
Connector bonded
to rebar.
Rigid
Conduit
To GFCI, Circuit
Breaker and
Power Source.
Содержание JandyColors JPL1230
Страница 2: ......