6.1 

To Operate the Light

Turn the light

 ON

. The 

fi

 rst

 time the light is

 

turned on, the color change sequence begins with the 

Alpine White color set and then continues through the sequence. The light cycles through 10 color set 
changes. Each color set is active for approximately 20 seconds before the light transitions to the next color 
(see Table 1). 

Table 1.  Pool and Spa Lights Color Change Sequence

Sequence Order

Color Set (Consists of Two Colors in Each Light)

1

Alpine White (first cycle only)

2

Sky Blue

3

Cobalt Blue

4

Caribbean Blue

5

Spring Green

6

Emerald Green

7

Emerald Rose

8

Magenta

9

Garnet Red

10

Violet (color remains active approximately 4 minutes)

NOTE

   When the light is first turned on, the sequence ends at Violet and at the next rotation, starts at Sky Blue. 

Alpine White is not included in subsequent cycles.

When the light is turned off, it will remain in the color set that is currently active. When the light is turned 
back on, the color change sequence will start with the color set that was last active. For example, if the light 
is turned off when Cobalt Blue color set is active, then Cobalt Blue will be the first color set in the change 
sequence when the light is turned on again.

6.2 

To Lock On a Speci

fi

 c Color Set

Wait until the desired color is ON during the 

fi

 rst cycle of color change

. Turn the light OFF, wait 2seconds 

and then turn the light back ON. Wait 10 seconds before turning the light off so that the color will not reset.

NOTE  

If a specific color is not locked on during first cycle of colors, the light will continue to follow the color change 
sequence. To choose a color 

after

 the first cycle, the light must be reset.

If you encounter a dimmed light, the light was probably turned off during in the middle of the color transition. 
To resolve this situation, turn the light off for 3 seconds, then turn it back on. The light will return to full power.

6.3 

To Initiate a New Cycle or Reset from a Locked Color

Turn the light OFF, wait 2 seconds, then turn ON, wait 2 seconds, then turn OFF, wait 2 seconds, and then 
turn ON again.  The light will return to beginning of the color cycle (Alpine White) and continue with the 
normal light sequence (see Table 1 in Section 6.1). 

NOTE

 

To synchronize colors on multiple 

Jandy Pool and Spa Light

 systems wired to separate switches, perform 

the above actions on all of their switches simultaneously.   All 

Jandy Digital Pool and Spa Lights

 will 

synchronize automatically if activated off of the same switch.  No other accessories are required.

Содержание JandyColors JPL120100

Страница 1: ...ed by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury...

Страница 2: ......

Страница 3: ...9 4 2 Replacing the Light Fixture 9 Section 5 Wiring Options for Controlling Jandy Pool Lights or Jandy Spa Lights 11 5 1 Wiring to an AquaLink RS Control System 11 5 2 Wiring to a Time Clock 12 Secti...

Страница 4: ...d which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Read and follow the specific instructions below...

Страница 5: ...AC 30 feet JPL12030 Jandy Pool Light 120 Volt AC 50 feet JPL12050 Jandy Pool Light 120 Volt AC 100 feet JPL120100 Jandy Pool Light 120 Volt AC 150 feet JPL120150 Jandy Spa Light 12 Volt AC 30 feet JSL...

Страница 6: ...r spas c c The light fixture and all metal items within five 5 feet of the pool or spa must be properly The light fixture and all metal items within five 5 feet of the pool or spa must be properly ele...

Страница 7: ...ound the light allows the light to be serviced after the pool or spa is filled with water 2 Cut the cord at the Junction Box leaving at least six 6 inches of cord to make connections 3 Strip six 6 inc...

Страница 8: ...lly grounds the housing securely to the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa use...

Страница 9: ...oltage transformer must be located at least The Junction Box or for 12 volt models the low voltage transformer must be located at least 8 inches above ground or water level at least four 4 inches abov...

Страница 10: ...ectrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock 3 Remove Junction Box cover disconnect the light fixture wires and strai...

Страница 11: ...nization must be operated at the same time to assure color synchronization otherwise the otherwise the lights will work independently of each other lights will work independently of each other 5 1 Wir...

Страница 12: ...iring Diagram GFCI Ground Ground Neutral Black White Green 12V Jandy Light Black White Green 120V 12V Transformer 120 VAC Power Supply 5 2 Wiring to a Time Clock The Jandy Pool and Spa Lights can be w...

Страница 13: ...Blue will be the first color set in the change sequence when the light is turned on again 6 2 To Lock On a Specific Color Set Wait until the desired color is ON during the first cycle of color change...

Страница 14: ...the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to elect...

Страница 15: ...ght new bulbs four 4 sets of P N R0399600 for Jandy Pool Light Jandy Pool Light or four 4 sets of or four 4 sets of P N R0400300 for P N R0400300 for Jandy Spa Light Jandy Spa Light Do not touch the b...

Страница 16: ...heck to see that the clamp is properly installed around the entire flange It is important to have the screw already started in is properly installed around the entire flange It is important to have th...

Страница 17: ...does not recommend installing 12 volt lights with cord lengths greater than 50 feet A significant voltage drop will occur that dramatically reduces the light output and possibly unit failure Wires fro...

Страница 18: ...t 3 N A Bulb Holder and Electronics Assembly Pool NO Purchase New Light 4 R0399600 Bulb Kit 75 Watt Halogen MR 16 EYC 2 bulbs in kit 8 bulbs required per light YES 5 R0399700 Dichroic Lens Holder Asse...

Страница 19: ...tronics Assembly Spa NO Purchase New Light 4 R0400300 Bulb Kit 25 Watt Halogen G 4 Capsule 12 Volt AC 2 bulbs per kit 8 bulbs required per light YES 5 R0400400 Dichroic Lens Holder Assembly Spa YES 6...

Страница 20: ...es outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or imprope...

Отзывы: