background image

Page 4

Section 1. Safety Information

IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE,

 ELECTRIC SHOCK, OR INJURY TO PERSONS 

READ AND FOLLOW ALL INSTRUCTIONS

When installing and using this electrical equipment, basic safety precautions should always be followed, 
including the following:

        

 

 

 

SAVE THESE INSTRUCTIONS

  WARNING

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. 

This underwater light must be installed by 

a licensed or certified electrician in accordance with the National Electrical Code and applicable local 
codes and ordinances.  Improper installation will create an electrical hazard, which could result in 
death or serious injury to pool or spa users, installers, or others due to electrical shock, and may also 
cause damage to property.  Read and follow the specific instructions below.

  WARNING

Before installing this underwater light, read and follow all warning notices and instructions 
accompanying this light. Failure to follow safety warnings and instructions can result in severe injury, 
death, or property damage. Call (707) 776-8200 for additional free copies of these instructions.

 ATTENTION INSTALLER: 

 This manual contains important information about the 

installation, operation and safe use of this product. This information should be given to the 
owner/operator of this equipment.

  NOTICE

These lights are intended for installation in fresh water swimming pools and spas only.

Содержание JandyColors JPL120100

Страница 1: ...ed by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury...

Страница 2: ......

Страница 3: ...9 4 2 Replacing the Light Fixture 9 Section 5 Wiring Options for Controlling Jandy Pool Lights or Jandy Spa Lights 11 5 1 Wiring to an AquaLink RS Control System 11 5 2 Wiring to a Time Clock 12 Secti...

Страница 4: ...d which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Read and follow the specific instructions below...

Страница 5: ...AC 30 feet JPL12030 Jandy Pool Light 120 Volt AC 50 feet JPL12050 Jandy Pool Light 120 Volt AC 100 feet JPL120100 Jandy Pool Light 120 Volt AC 150 feet JPL120150 Jandy Spa Light 12 Volt AC 30 feet JSL...

Страница 6: ...r spas c c The light fixture and all metal items within five 5 feet of the pool or spa must be properly The light fixture and all metal items within five 5 feet of the pool or spa must be properly ele...

Страница 7: ...ound the light allows the light to be serviced after the pool or spa is filled with water 2 Cut the cord at the Junction Box leaving at least six 6 inches of cord to make connections 3 Strip six 6 inc...

Страница 8: ...lly grounds the housing securely to the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa use...

Страница 9: ...oltage transformer must be located at least The Junction Box or for 12 volt models the low voltage transformer must be located at least 8 inches above ground or water level at least four 4 inches abov...

Страница 10: ...ectrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock 3 Remove Junction Box cover disconnect the light fixture wires and strai...

Страница 11: ...nization must be operated at the same time to assure color synchronization otherwise the otherwise the lights will work independently of each other lights will work independently of each other 5 1 Wir...

Страница 12: ...iring Diagram GFCI Ground Ground Neutral Black White Green 12V Jandy Light Black White Green 120V 12V Transformer 120 VAC Power Supply 5 2 Wiring to a Time Clock The Jandy Pool and Spa Lights can be w...

Страница 13: ...Blue will be the first color set in the change sequence when the light is turned on again 6 2 To Lock On a Specific Color Set Wait until the desired color is ON during the first cycle of color change...

Страница 14: ...the mounting ring and wet niche Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to elect...

Страница 15: ...ght new bulbs four 4 sets of P N R0399600 for Jandy Pool Light Jandy Pool Light or four 4 sets of or four 4 sets of P N R0400300 for P N R0400300 for Jandy Spa Light Jandy Spa Light Do not touch the b...

Страница 16: ...heck to see that the clamp is properly installed around the entire flange It is important to have the screw already started in is properly installed around the entire flange It is important to have th...

Страница 17: ...does not recommend installing 12 volt lights with cord lengths greater than 50 feet A significant voltage drop will occur that dramatically reduces the light output and possibly unit failure Wires fro...

Страница 18: ...t 3 N A Bulb Holder and Electronics Assembly Pool NO Purchase New Light 4 R0399600 Bulb Kit 75 Watt Halogen MR 16 EYC 2 bulbs in kit 8 bulbs required per light YES 5 R0399700 Dichroic Lens Holder Asse...

Страница 19: ...tronics Assembly Spa NO Purchase New Light 4 R0400300 Bulb Kit 25 Watt Halogen G 4 Capsule 12 Volt AC 2 bulbs per kit 8 bulbs required per light YES 5 R0400400 Dichroic Lens Holder Assembly Spa YES 6...

Страница 20: ...es outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or imprope...