![Jandy Jandy Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/jandy/jandy/jandy_installation-and-operation-manual_3309574005.webp)
Page 5
ENGLISH
Jandy
®
Slide Valve & Backwash Valve
|
Installation & Operation Manual
Non-Jandy
Filter
Jandy DEL Series
Filters
Jandy
JS and DEV Series
Filters
Jandy
SFSM Series
Filter
8” Shaft
8” Shaft
7.5” Shaft
8” Shaft
Figure 3. Jandy Slide and Backwash Valve Filter Connections
Slide and Backwash Models
Filter Model
BWVL-SLD
BWVL-SLD-75
SVLV8
SVLV2
Jandy JS Series
X
Jandy DEV Series
X
Jandy SFSM Series
X
Jandy DEL Series
X
Non-Jandy Filters*
X*
*Also Requires Versa Coupler Kit 8044
Table 1. Slide and Backwash Models
b. Normal Operation
WARNING
NEVER
attempt to assemble,
disassemble or adjust the filter when
there is pressurized air in the system.
Starting the pump while there is
any pressurized air in the system
can cause the filter lid to be blown
off, which can cause death, serious
personal injury or property damage.
1. Turn off the system pump(s).
2.
Ensure that the slide valve handle is fully
extended (handle pulled all the way up).
3. Turn on the filter pump(s).
4. Open the air release valve on top of the filter tank
to release all pressure from inside the tank and
system. Wait for all the air to evacuate the system
and then close the air release valve.
5. Check the system for normal water flow.
c. Backwash Mode
1. Turn off the system pump(s).
2.
Ensure that the slide valve handle is fully
depressed with handle and piston pushed all the
way down.
3.
Turn the handle until the stainless steel pin on
the piston locks into the position bracket.
4. Turn on the system pump(s).
5. Open the air release valve on top of the filter
tank to release all pressure from inside the tank
and system. Wait for all the air to evacuate the
system and then close the air release valve.
6. Run the system until the waste water runs clean.
• Be sure to follow any and all applicable local
codes related to proper discharge/drainage of
water from your pool/spa.
7. Turn off the system pump(s).
8. Return the slide valve handle to the normal
operating position. See Figure 2.
9.
Turn on system pump(s) and check for normal
water flow.