WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION,
which could result in serious injury or death.
A Ground Fault
Circuit Interrupter (GFCI) must be provided for 120 Volt transformers.
The conductors on the load side of the GFCI circuit shall not occupy
conduit, boxes, or enclosures containing other conductors unless the
additional conductors are also protected by a GFCI. Refer to local
codes for complete details.
WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION,
which could result in serious injury or death.
The Jandy
Pro Series Nicheless LED Lights are only available for 12-volt
AC power. Use ONLY a 120VAC to 12 VAC step-down, class 2
transformer which is NRTL-listed/certified for the application. For
more information about 12-volt installations, refer to
Section 5
of this
manual.
3.2
Wiring to a Time Clock
The Jandy Pro Series Nicheless LED Lights can be wired to a time
clock to operate the lights automatically.
3.3
Wiring to a Switch
The Jandy Pro Series Nicheless LED Lights can be wired into a switch
to manually operate the lights. Refer to Figure 4 to connect the lights
into the switch.
AquaLink Aux
Black
GFCI
120 volts to
12VAC
Transformer
White
Ground
Line
Neutral
Ground
Black
Black
White
White
Green
Relay or Switch
Wiring Jandy Pro Series Nicheless Underwater Lights
4
Figure 4. Wiring Jandy Pro Series Nicheless Underwater Lights