background image

Installation Guide

X-Last Bollards

Option 1 - Concrete in root

Excavate or core drill a minimum foundation size of:

Solid Ground

Bollard di 100mm x 205mm deep

Loose Ground

600 x 600 x 400mm deep

IMPORTANT

Do not allow concrete

to enter the bollard.

Add a sand bedding for bollard to sit on.

Place bollard centrally in foundation and pour ST4

concrete, using a level ensure bollard is vertical. Allow 

enough depth for any finishing surface.

Ensure the top of the ring is flush with finished surface 

level.

Option 2 - Bolt down flange plate

Use M16 bolts for bolting down to good concrete base. 

Length of bolt is dependent on ground conditions.

Sand

205m

m

Bollard dia.

+ 100mm

Top of ring flush

with surface level

ST4 Concrete

50m

m

50m

m