Jandy ePump Скачать руководство пользователя страница 3

Page 3

Table of Contents

Section 1.  Important Safety Instructions ........ 4

Section 2.  Installation of the User Interface ... 6

2.1 Introduction 

......................................................... 6

2.2 

The User Interface Panel .................................... 6

2.3 

The User Interface Components ......................... 6

2.4 

Installation of the Backplate onto an 
Electrical Box ...................................................... 6

2.5 

Installation of the Backplate on a Flat Wall ......... 7

2.6 

Connection to the Jandy ePump

TM

 Variable 

Speed Pump ....................................................... 7

2.7 

Jandy ePump™ Variable Speed Pump Switch 
Settings ............................................................... 7

2.8 

Connection to Remote Contacts ......................... 8

2.9 Remote 

Operation 

.............................................. 8

2.10  Remote Closure 4 Behavior ................................ 8

Section 3.  User Operation ................................ 9

3.1 OFF 

Mode 

........................................................... 9

3.2 RUN 

Mode 

.......................................................... 9

3.3 

Manual Start and Stop ........................................ 9

3.4 

Pump Speed Setting ........................................... 9

3.5 

Timeclock Setup and Operation........................ 10

Section 4.  Service Setup Options ................. 11

4.1 

Entering Service Setup ..................................... 11

4.2 

Minimum and Maximum Pump Speeds ............ 11

4.3 Load 

Defaults 

.................................................... 11

4.4 Last 

Fault 

.......................................................... 12

4.5 

Priming Speed and Duration ............................. 12

4.6 eStar 

Speed 

...................................................... 12

4.7 

Pump Freeze Protect Operation ....................... 12

4.8 Selecting 

Pump 

Type 

........................................ 13

Section 5.  User Set Up Options ..................... 13

5.1 Setting 

Time-of-Day 

.......................................... 13

5.2 Labeling 

Presets 

............................................... 13

5.3 General 

Labels 

................................................. 14

5.4 Custom 

Labels 

.................................................. 14

5.5 

Display Light Control ......................................... 14

5.6 Language 

Selection 

.......................................... 14

5.7 

Run Duration (Presets 3 and 4 Only) ................ 14

Section 6.  Menu Flow Chart ........................... 15

DATE OF INSTALLATION

INSTALLER INFORMATION

INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)

PUMP MODEL

 

HORSEPOWER

FILTER MODEL

 

SERIAL NUMBER

CONTROLLER MODEL 

SERIAL NUMBER

NOTES:

EQUIPMENT INFORMATION RECORD

Содержание ePump

Страница 1: ...serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious i...

Страница 2: ......

Страница 3: ...d Stop 9 3 4 Pump Speed Setting 9 3 5 Timeclock Setup and Operation 10 Section 4 Service Setup Options 11 4 1 Entering Service Setup 11 4 2 Minimum and Maximum Pump Speeds 11 4 3 Load Defaults 11 4 4...

Страница 4: ...broken or missing Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly WARNING To Reduce the Risk of Injury a The water in a spa should never exceed...

Страница 5: ...trant dans une cuve de relaxation et en sortant Pour viter l vanouissement et la noyade ventuelle ne prendre ni drougue ni alcool avant d utiliser une cuve de relaxation ni quand on s y trouve Les fem...

Страница 6: ...crews 6 Plastic Film Additional materials are required for the installation of the user interface and must be supplied by the installer 1 A cable to connect the pump to the remotely mounted user inter...

Страница 7: ...ump electrical circuit before starting the procedure Failure to comply may cause a shock hazard resulting in severe personal injury or death 2 Remove the cover of the pump junction box 3 Feed the RS 4...

Страница 8: ...o comply may cause a shock hazard resulting in severe personal injury or death 2 Install the normally closed reman s switch to the timeclock assembly See timeclock manufacturer s instructions for deta...

Страница 9: ...rted from the controller Manual operation of speeds eStar through 4 differs from manual operation of speeds 5 through 8 NOTE When starting the pump the pump will first run at the priming speed for the...

Страница 10: ...UN mode 2 3 4 ePUMP MENU 2 PRESET 2 TIMECLOCK ENABLE 3 5 2 Timeclock Operation When the pump is stopped the associated green LED will illuminate indicating a timeclock program is enabled for that spee...

Страница 11: ...enu press and hold MENU then press and hold the and preset 4 keys Hold all three 3 keys down for five 5 seconds To exit press any preset button 2 3 4 ePUMP MENU PRESS PRESET OR MENU 12 00AM PUMP IS OF...

Страница 12: ...ing the arrow keys set the priming speed to the desired value Press MENU to accept and store 2 3 4 PRIMING SPEED RPM 3450 ePUMP MENU To set priming duration select PRIMING DURATION using the arrow key...

Страница 13: ...s time the ePump controller does not support other types of pumps Section 5 User Set Up Options NOTE The ePumpTM user interface must be in the OFF mode before entering the user setup mode While in set...

Страница 14: ...keys select the desired operating mode for the display backlight LIGHT OFF Turn off display backlight LIGHT ON Turn on display backlight 2 MIN TIMEOUT Turn on display backlight with automatic turn of...

Страница 15: ...s not affected when LOAD DEFAULTS is executed 8 Key that is pressed to wake up display is also acted upon 9 Press and hold MENU eStar and 4 simultaneously for 5 seconds to enter 10 Setting not saved i...

Страница 16: ...lished minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizin...

Отзывы: