background image

Page 5 

ENGLISH

  

 

Jandy

®

 Pro Series, CS Single Element Cartridge Pool & Spa Filter   

|

   Installation & Operation Manual

Section 2.  General Information

2.1 Introduction

This manual contains information for the proper 

installation and operation of the Jandy Pro Series CS 

Cartridge Filters. Procedures in this manual must be 

followed exactly. For technical assistance, contact our 

Technical Support Department at 1.800.822.7933.

2.2 Description

Cartridge filters do not require sand or diatomaceous earth 

as the filter medium. Instead they contain a filter cartridge 

element which is easily removed for cleaning or replacement.

Dirty water flows into the filter tank and is directed 

through the filter cartridge. The debris is collected on the 

surface of the cartridge as the water flows through it. The 

water will travel through the central filter core towards 

the bottom of the filter into the lower manifold. Clean 

water is returned to the swimming pool through the filter 

outlet port at the tank's bottom.

As debris collects in the filter, the pressure will rise and 

water flow to the pool will diminish. The filter cartridge 

must be cleaned when the operating pressure of the 

filter rises 10 psi from the operating pressure of a clean 

cartridge. See Section 6 "Cleaning the Filter". 

NOTE

  A filter removes dirt and other suspended particles 

but does not sanitize the pool. Pool water must be 

sanitized and chemically balanced for clear water. 

The filtration system should be designed to meet 

local health codes. At a minimum, the system should 

turnover the total volume of water in your pool two (2) 

to four (4) times in a 24 hour period.

2.3  General Requirements

1. 

For best overall performance place the system as 

close to the pool as possible.

2. 

The filter should be located on a level concrete 

slab so that the orientation of the valve outlets and 

the pressure gauge are convenient and accessible 

for the installation and operation of the unit.

3. 

Protect the filter from the weather.

4. 

If fitting a chlorinator and/or any other device into 

the filtration plumbing circuit, great care must be 

exercised to ensure that the appliance is installed 

in accordance with the Manufacturer’s Instructions 

and any applicable standards that may exist.

5. 

Use Jandy Pro Series universal unions to connect 

each component of the water conditioning system 

for future servicing. All Jandy Pro Series filters 

come with these type of fittings.

 WARNING

The maximum operating pressure for this filter is 50 

psi. Never subject the filter to operating pressure 

exceeding 50 psi. Operating pressures above 50 psi 

can cause product failure or also cause the lid to be 

blown off, which can result in death, serious personal 

injury, or property damage.

6. 

When performing hydrostatic pressure tests or 

when testing for external leaks of the completed 

filtration and plumbing system, ensure that 

the maximum pressure the filtration system is 

subjected to 

does not exceed the maximum 

working pressure of any of the components 

within the system. 

Section 3.  Installation Instructions

 WARNING

Use equipment only in a pool or spa installation. Do not 

connect system to an unregulated city water system or 

other external source of pressurized water producing 

pressures greater than 35 psi.

3.1  Filter Location

WARNING

To Reduce the Risk of Fire, install pool equipment in 

an area where leaves or other debris will not collect 

on or around the equipment. Keep surrounding area 

clear of all debris such as paper, leaves, pine-needles 

and other combustible materials.

1. 

Select a well-drained area, one that does not flood 

when it rains. Damp, non-ventilated areas should 

be avoided.

2. 

The filter should be installed on a firm, solid, and level 

surface or platform to avoid risk of settlement. Do not 

use sand to level the filter as the sand will wash away; 

filter systems can weight up to 300pounds. Check 

local building codes for additional requirements. 

(Ex. Equipment pads in Florida must concrete and 

equipment must be secured to the pad.)

3. 

Install electrical controls at least five (5) feet from 

the filter. This will allow enough room to stand away 

from the filter during start-up.

4. 

Allow sufficient clearance around the filter to permit 

a visual inspection of the clamp ring. See Fig. 1.

Содержание CS150

Страница 1: ...follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation...

Страница 2: ......

Страница 3: ...lation Instructions 5 3 1 Filter Location 5 3 3 Filter Installation 6 3 4 Locking Ring Tank Top Assembly Installation 7 Section 4 Start Up and Operation 8 4 1 New Pool and Seasonal Start up 8 Section...

Страница 4: ...Y INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressur...

Страница 5: ...or any other device into the filtration plumbing circuit great care must be exercised to ensure that the appliance is installed in accordance with the Manufacturer s Instructions and any applicable s...

Страница 6: ...r See Fig 2 NOTE Teflon tape is included in the accessory bag 3 3 Filter Installation WARNING To avoid an electrical shock hazard which can result in serious injury or death ensure that all electrical...

Страница 7: ...the equipment pad with a masonry bit Use the holes in the tank bottom base as a guide 11 Install x 2 Stainless Steel Tapcon screws and tighten 3 4 Locking Ring Tank Top Assembly Installation WARNING F...

Страница 8: ...ON DO NOT operate filter at water temperatures above 105 F 40 6 C Water temperatures above the manufacturer s recommendations will shorten the life span of the filter and void the warranty 4 1 New Poo...

Страница 9: ...service technician 5 Product safety signs or labels should be periodically inspected and cleaned by the product user as necessary to maintain good legibility for safe viewing 6 Product safety signs or...

Страница 10: ...any filter isolation valves to prevent flooding 3 Open the air release valve on top of the filter and wait for all air pressure to be released 4 Loosen the drain plug at the base of the filter to ensu...

Страница 11: ...t line Fill pump with water at basket and replace lid Technician required Technician or electrician required Short filter cycles Presence of algae clogging filter Incorrect water chemistry Strainer ba...

Страница 12: ...50 Sq Ft CS250 R0462500 5 Tailpiece Cap and Union Nut Set Set of 3 2 x 2 1 2 R0461800 5 Tailpiece Cap and Union Nut Set Set of 3 50mm R0462600 6 Breather Tube CS100 CS150 R0462801 6 Breather Tube CS20...

Страница 13: ...200 250 Normal Start Up PSI 6 15 6 15 6 15 6 15 Max Working PSI 50 50 50 50 Residential Specifications Maximum Flow gpm 100 125 125 125 6 Hour Capacity gallons 36 000 45 000 45 000 45 000 8 Hour Capac...

Страница 14: ...ter Installation Operation Manual 18 1 2 3 1 4 A 14 3 4 Figure 7 Dimensions CS Cartridge Series Filter Figure 8 Dimensions CS Cartridge Series Filter Top View Outlet Port Inlet Port Drain Port 13 20 1...

Страница 15: ...Page 15 ENGLISH Jandy Pro Series CS Single Element Cartridge Pool Spa Filter Installation Operation Manual NOTES...

Страница 16: ...Inc 2 3365 Mainway Burlington Ontario L7M 1A6 1 888 647 4004 www ZodiacPoolSystems ca 2018 Zodiac Pool Systems LLC ZODIAC is a registered trademark of Zodiac International S A S U used under license A...