ENGLISH

  

 

Jandy

®

 Pro Series, CS Single Element Cartridge Pool & Spa Filter   

|

   Installation & Operation Manual

3. 

Open the air release valve on top of the filter and 

wait for all air pressure to be released.

4. 

Open the filter tank drain. When the filter tank has 

drained, close the drain. Place it upright in a area 

suitable for washing.

5. 

Open filter tank and remove cartridge element, 

see Section 5.1 "Filter Element Removal". Place 

it upright in an area suitable for washing.

6. 

Use a garden hose and nozzle to wash each pleat 

of the element.

NOTE

  Algae, suntan oil, calcium and body oils can form 

coatings on filter element which may not be removed 

by normal hosing. To remove such materials, soak the 

element in de-greaser and then a de-scaler. Your local 

pool shop will be able to recommend suitable products.

7. 

Replace the cartridge back into the filter tank. 

Inspect the o-ring for cracks or wear marks. Place 

the o-ring back onto the filter tank top. Replace 

the top of the tank. See Section 3.4 "Locking 

Ring/Tank Top Assembly Installation". 

8. 

Reopen the isolation valves if they were closed.

9. 

Stand clear of the filter, start the pump and 

circulate the water until water sprays out of the 

air release valve. Close the air release valve. The 

filter is now back in operating mode.

10.  Watch the pressure gauge to be sure that the 

pressure does not exceed 50 psi. If the pressure 

approaches 50 psi, immediately turn the pump 

off and clean the filter cartridges. If the pressure 

remains high after cleaning the filter, refer to the 

troubleshooting guide, Section 8, for possible 

causes and solutions.

6.4  Breather Tube Maintenance

1. 

Turn 

off

 the filter pump and switch off the circuit 

breaker to the pump motor.

2. 

If the filter is installed below pool level, close any 

filter isolation valves to prevent flooding.

3. 

Open the air release valve on top of the filter and 

wait for all air pressure to be released.

4. 

Loosen the drain plug at the base of the filter to 

ensure the tank is empty.

5. 

Open the filter tank.

6. 

Check breather tube for obstructions or debris. 

If necessary, remove the breather tube and flush 

with running water until the obstruction or debris 

is cleared. See Figure 7.

7. 

If the obstruction or debris can not be removed 

or the breather tube is damaged, 

STOP

 using the 

filter immediately and replace the breather tube 

assembly.

 WARNING

If the breather tube is not fully seated 

or is damaged or clogged, trapped 

air can cause product failure or also 

cause the filter lid to be blown off 

which can result in death, serious 

personal injury or property damage.

8. 

Reassemble breather tube.  Fully seat the breather 

tube into the bottom tank.

9. 

Replace the filter locking ring/tank top assembly 

on the filter and tighten. See Section 3.4 "Locking 

Ring/Tank Top Assembly Installation".

10.  Reopen isolation valve if they were closed.

11.  Stand clear of the filter, start the pump and 

circulate the water until water sprays out of the 

air release valve. Close the air release valve. The 

filter is now back in operating mode.

12.  Watch the pressure gauge to be sure that the 

pressure does not exceed 50 psi. If the pressure 

approaches 50 psi, immediately turn the pump 

off and clean the filter cartridges. If the pressure 

remains high after cleaning the filter, refer to the 

troubleshooting guide, Section 8, for possible 

causes and solutions.

Section 7.  Winterizing

1. 

Turn 

off

 the filter pump and switch off the circuit 

breaker to the pump motor.

2. 

Open air release valve on top of the filter. 

Do not 

remove.

3. 

Loosen the drain nut and cap at the base of the 

filter to ensure that the tank is empty. 

4. 

Drain circulation system of all water.

5. 

Cover the system with a tarpaulin or plastic sheet 

to protect it from the weather.

Содержание CS150

Страница 1: ...follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation...

Страница 2: ......

Страница 3: ...lation Instructions 5 3 1 Filter Location 5 3 3 Filter Installation 6 3 4 Locking Ring Tank Top Assembly Installation 7 Section 4 Start Up and Operation 8 4 1 New Pool and Seasonal Start up 8 Section...

Страница 4: ...Y INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressur...

Страница 5: ...or any other device into the filtration plumbing circuit great care must be exercised to ensure that the appliance is installed in accordance with the Manufacturer s Instructions and any applicable s...

Страница 6: ...r See Fig 2 NOTE Teflon tape is included in the accessory bag 3 3 Filter Installation WARNING To avoid an electrical shock hazard which can result in serious injury or death ensure that all electrical...

Страница 7: ...the equipment pad with a masonry bit Use the holes in the tank bottom base as a guide 11 Install x 2 Stainless Steel Tapcon screws and tighten 3 4 Locking Ring Tank Top Assembly Installation WARNING F...

Страница 8: ...ON DO NOT operate filter at water temperatures above 105 F 40 6 C Water temperatures above the manufacturer s recommendations will shorten the life span of the filter and void the warranty 4 1 New Poo...

Страница 9: ...service technician 5 Product safety signs or labels should be periodically inspected and cleaned by the product user as necessary to maintain good legibility for safe viewing 6 Product safety signs or...

Страница 10: ...any filter isolation valves to prevent flooding 3 Open the air release valve on top of the filter and wait for all air pressure to be released 4 Loosen the drain plug at the base of the filter to ensu...

Страница 11: ...t line Fill pump with water at basket and replace lid Technician required Technician or electrician required Short filter cycles Presence of algae clogging filter Incorrect water chemistry Strainer ba...

Страница 12: ...50 Sq Ft CS250 R0462500 5 Tailpiece Cap and Union Nut Set Set of 3 2 x 2 1 2 R0461800 5 Tailpiece Cap and Union Nut Set Set of 3 50mm R0462600 6 Breather Tube CS100 CS150 R0462801 6 Breather Tube CS20...

Страница 13: ...200 250 Normal Start Up PSI 6 15 6 15 6 15 6 15 Max Working PSI 50 50 50 50 Residential Specifications Maximum Flow gpm 100 125 125 125 6 Hour Capacity gallons 36 000 45 000 45 000 45 000 8 Hour Capac...

Страница 14: ...ter Installation Operation Manual 18 1 2 3 1 4 A 14 3 4 Figure 7 Dimensions CS Cartridge Series Filter Figure 8 Dimensions CS Cartridge Series Filter Top View Outlet Port Inlet Port Drain Port 13 20 1...

Страница 15: ...Page 15 ENGLISH Jandy Pro Series CS Single Element Cartridge Pool Spa Filter Installation Operation Manual NOTES...

Страница 16: ...Inc 2 3365 Mainway Burlington Ontario L7M 1A6 1 888 647 4004 www ZodiacPoolSystems ca 2018 Zodiac Pool Systems LLC ZODIAC is a registered trademark of Zodiac International S A S U used under license A...

Отзывы: