background image

Page 4 

ENGLISH

  

 

Jandy

®

 Pro Series, CS Single Element Cartridge Pool & Spa Filter   

|

   Installation & Operation Manual

 

WARNING

•  Do not connect system to an unregulated city water system or other external source of 

pressurized water producing pressures greater than 35 PSI.

•  Pressurized air in system can cause product failure or also cause the filter lid to be blown off 

which can result in death, serious personal injury, or property damage. Be sure all air is out 

of system before operating or testing the equipment.

 

WARNING

MAXIMUM OPERATING PRESSURE OF THE FILTER IS 50 PSI. NEVER SUBJECT THE 

FILTER TO ANY OPERATING PRESSURE EXCEEDING 50 PSI.

This filter operates under high pressure. When any part of the circulating system, i.e., filter, 

pump, valve(s), clamp, etc. is serviced, air can enter the system and become pressurized when 

the system is restarted. Pressurized air can cause product failure or also cause the filter lid to 

be blown off which can result in death, serious personal injury or property damage. To avoid this 

potential hazard, follow all of the instructions in this manual.

 

WARNING

To minimize risk of severe injury or death the filter and/or pump should not be subjected to the 

piping system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These 

requirements are generally not intended to apply to the pool equipment such as filters or pumps.
Jandy Pro Series pool equipment is pressure tested at the factory.
If however this WARNING cannot be followed and pressure testing of the piping system must include 

the filter and/or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:

•  Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed 

and secured before testing.

•  RELEASE ALL AIR

 in the system before testing.

•  Water pressure for test must NOT EXCEED 35 PSI.
•  Water temperature for test must NOT EXCEED 100°F (38°C).
•  Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.  

Notice

: These parameters apply to Jandy Pro Series equipment only. For non-Jandy equipment, consult equipment manufacturer.

Section 1.  Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS

1.1  Important Safety Warning

1.2  General Safety Instructions

ATTENTION INSTALLER

This manual contains important information about the installation, operation and safe use of this 

product. This information should be given to the owner/operator of this equipment.

1. 

Use equipment only in a pool or spa installation.

2. 

Before repositioning valve(s) and before beginning the assembly, disassembly, or adjustment of the clamp, 

or any other service of the circulating system; (A) 

turn the pump off

 and shut off any automatic controls to 

ensure the system is not inadvertently started during servicing; (B) open the air release valve; (C) wait until all 

pressure is relieved (air will have stopped flowing from the air release valve).

3. 

Whenever installing the filter clamp 

follow Section 3.4

 of this manual, 

“Locking Ring/Tank Top Assembly 

Installation”

.

4. 

Once service on the circulation system is complete, follow Section 4 of this manual, “Start-up and Operation”. 

5. 

Maintain circulation system properly. Replace worn or damaged parts immediately.

6. 

Be sure that the filter is properly mounted and positioned according to these installation instructions.

7. 

Do not pressure test above 35 PSI. Pressure testing must be done by a trained pool professional.

SAVE THESE INSTRUCTIONS

Содержание CS150

Страница 1: ...follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation...

Страница 2: ......

Страница 3: ...lation Instructions 5 3 1 Filter Location 5 3 3 Filter Installation 6 3 4 Locking Ring Tank Top Assembly Installation 7 Section 4 Start Up and Operation 8 4 1 New Pool and Seasonal Start up 8 Section...

Страница 4: ...Y INSTRUCTIONS Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressur...

Страница 5: ...or any other device into the filtration plumbing circuit great care must be exercised to ensure that the appliance is installed in accordance with the Manufacturer s Instructions and any applicable s...

Страница 6: ...r See Fig 2 NOTE Teflon tape is included in the accessory bag 3 3 Filter Installation WARNING To avoid an electrical shock hazard which can result in serious injury or death ensure that all electrical...

Страница 7: ...the equipment pad with a masonry bit Use the holes in the tank bottom base as a guide 11 Install x 2 Stainless Steel Tapcon screws and tighten 3 4 Locking Ring Tank Top Assembly Installation WARNING F...

Страница 8: ...ON DO NOT operate filter at water temperatures above 105 F 40 6 C Water temperatures above the manufacturer s recommendations will shorten the life span of the filter and void the warranty 4 1 New Poo...

Страница 9: ...service technician 5 Product safety signs or labels should be periodically inspected and cleaned by the product user as necessary to maintain good legibility for safe viewing 6 Product safety signs or...

Страница 10: ...any filter isolation valves to prevent flooding 3 Open the air release valve on top of the filter and wait for all air pressure to be released 4 Loosen the drain plug at the base of the filter to ensu...

Страница 11: ...t line Fill pump with water at basket and replace lid Technician required Technician or electrician required Short filter cycles Presence of algae clogging filter Incorrect water chemistry Strainer ba...

Страница 12: ...50 Sq Ft CS250 R0462500 5 Tailpiece Cap and Union Nut Set Set of 3 2 x 2 1 2 R0461800 5 Tailpiece Cap and Union Nut Set Set of 3 50mm R0462600 6 Breather Tube CS100 CS150 R0462801 6 Breather Tube CS20...

Страница 13: ...200 250 Normal Start Up PSI 6 15 6 15 6 15 6 15 Max Working PSI 50 50 50 50 Residential Specifications Maximum Flow gpm 100 125 125 125 6 Hour Capacity gallons 36 000 45 000 45 000 45 000 8 Hour Capac...

Страница 14: ...ter Installation Operation Manual 18 1 2 3 1 4 A 14 3 4 Figure 7 Dimensions CS Cartridge Series Filter Figure 8 Dimensions CS Cartridge Series Filter Top View Outlet Port Inlet Port Drain Port 13 20 1...

Страница 15: ...Page 15 ENGLISH Jandy Pro Series CS Single Element Cartridge Pool Spa Filter Installation Operation Manual NOTES...

Страница 16: ...Inc 2 3365 Mainway Burlington Ontario L7M 1A6 1 888 647 4004 www ZodiacPoolSystems ca 2018 Zodiac Pool Systems LLC ZODIAC is a registered trademark of Zodiac International S A S U used under license A...

Отзывы: