background image

5

Notes:

Input Current @ 240 VAC: ~ 1A
Input Current @ 120 VAC: ~ 1.3A

Input Freq.: 47 ~ 63 Hz.

Output Voltage: 25V DC (max.)

Output Current:

APURE35 – 5.0A DC

Dimensions:

Power Pak (L x W x H): 10” x 4.5” x 13”
Electrolytic Cell  (L x W x H): 6.5” x 5.5” x 12”
Pod (L x W x H): 6.5” x 5.5” x 6” (Plug-In Unit)

Weight:

Power Pak: 7 lbs.
Electrolytic Cell: 2 lbs.
Pod: 1.5 lbs. (Plug-In Unit)

Maximum Operating Pressure: 50 psi

Minimum Flow Rate: 40 gpm

Maximum Flow Rate: 92 gpm

Required Salt Level: 3.5 to 4.0 gpl (3,500 to 4,000 ppm)

Maximum water volume treated:

APURE35 – 35,000  gallons (132,000  litres)

Chlorine Output:       

APURE35 – 0.62 ounce (17.5 grams) per hour.

Voltage: 

Plug-In Unit : 120V 
Hard Wired Unit: 240V or 120V (the system auto detects)

Input Voltage: 95 – 265 VAC 

Specifications:
AquaPure

®

Ei Series

Models:

Hard Wired Unit part number – APURE35
Plug-In Unit part number – APURE35PLG

Hard Wired Unit - Dual Voltage 240/120 VAC
Plug-In  Unit – 120 VAC 
Up to 35,000 gallons 

Содержание AquaPure Ei

Страница 1: ...1 AquaPure Ei Chlorine Generator Workbook...

Страница 2: ...2...

Страница 3: ..._____ Sales person ________________________________________________ ext ________ ___________________________________________________________ ext ________ Service Manager ______________________________...

Страница 4: ...LECTRICAL LOW VOLTAGE 14 15 TESTINGCONNECTION 15 OPERATION 16 MANUALCELLREVERSAL 17 NO FLOW INDICATOR 18 CHECK SALT INDICATOR V2 0 18 CHECK SALT INDICATOR V2 10 19 20 OPERATIONWITHONETOUCH 21 22 ERROR...

Страница 5: ...rating Pressure 50 psi Minimum Flow Rate 40 gpm Maximum Flow Rate 92 gpm Required Salt Level 3 5 to 4 0 gpl 3 500 to 4 000 ppm Maximum water volume treated APURE35 35 000 gallons 132 000 litres Chlori...

Страница 6: ...R O n O f f O ut put Flow Salt R Power Pak Cell Upper Clamp Lower Clamp 1 inch Adapter Notes Components Plug In Unit Power Pak Pod Flow Switch 2 5 a m pfu s e s Blk Rd Fan O V POS B A 10 0 26 5VAC R...

Страница 7: ...minimum of straight pipe Notes Blk Rd Fan OV P OS B A R O n Of f Ou tpu t Flow Salt R R O n O f f O u t p u t F l o w Sal t R Cell should be the last piece of equipment Maximum 15 feet Water Flow Wat...

Страница 8: ...mbly Cell clamps Only needed if pipe is 1 inch Plumbing Use lower half as a guide to mark location for holes And here Plumbing Drill holes with the bit provided Caution Do not drill through other side...

Страница 9: ...9 Plumbing Clamp two halves together Insert Cell and tighten lock nut Electrical Remove cover for wiring Electrical Follow color coding Run cable down channel Replace cover when complete...

Страница 10: ...n Unit Plug Power Pack into GFCI receptacle Plug Pod into Power Pak Bond all equipment with bond wire included in kit Bl k Rd Fan OV POS B A R On Off Outp ut Flow Salt R R O n O f f O u t p u t Fl ow...

Страница 11: ...R On Of f Ou tput Flow Salt R Electrical Hard Wired Unit Press in on taps at each side then lift up from bottom to remove gray cover 2 5 amp fuses Blk Rd Fan OV POS B A 1 00 265VAC R R On Off Output F...

Страница 12: ...supply Unplug ribbon cable from PCB if necessary Wiring to controller 2 5 am p f use s Blk Rd OV POS B A 100 265 V A C Electrical Hard Wired Unit Wire either 120 or 240 VAC to terminals 2 4 of power...

Страница 13: ...L M Some controllers require different interface protocols The Ei has 3 different modes depending on which controller it will be connected to The default is set to Jandy L M To change turn the Ei OFF...

Страница 14: ...g on the size of the cable being used Cable tie Terminal block To reduce strain on the cable attach a cable tie to the communication cable as shown Test the Connection To insure the controller and Ei...

Страница 15: ...ade salt with the following characteristics Salt AquaPure Ei 3 500 to 4 000 PPM Ocean water 36 000 PPM Tear drop 7 200 PPM Operation Operation 2 5 ampfuses B lk Rd Fan OV POS B A 1 00 26 5 VAC R On Of...

Страница 16: ...Off Output Flow Salt R ON As a stand alone chlorinator the output is measured in 20 increments When interfaced with a controller the Ei will accept any increment but will round the output light to th...

Страница 17: ...nder the Jandy logo for 4 seconds The output at the cell will turn off momentarily the polarity will reverse and the output will turn back on Hidden polarity button under the Jandy logo Polarity Rever...

Страница 18: ...a worn or damaged electrode The ideal salt level is 4000 ppm and the ideal water temperature is 80 F The CHECK SALT light will illuminate the LCD will read Check Salt if the water temp is below 65 th...

Страница 19: ...ll read Check Salt or Low Temperature The Check Salt light will NOT illuminate until the water temperature is near freezing AND the salt level falls to 3000 ppm or less The LCD message can occur at a...

Страница 20: ...enough or the salt low enough that the Ei will not be able to generate desired amount of chlorine Solutions Add salt until the indicator turns off This may require higher salt levels than recommended...

Страница 21: ...PASSWORD PROGRAM GROUP SYSTEM SETUP BOOST Ei With Aqualink RS Changing the Ei output from the Aqualink RS screen BACK DONE SELECT SET AquaPure SET TO 15 Use ARROW KEYS to set value Then SELECT Normal...

Страница 22: ...low salt is 2900 ppm The actual salt level may be lower BACK DONE SELECT EQUIPMENT STATUS AquaPure 15 SALT 2900 PPM CHECK AquaPure Low Salt FILTER PUMP NO FLOW on Ei being displayed on the Aqualink BA...

Страница 23: ...When connected to a controller and SPA mode is selected at the controller the output of the Ei will drop to 20 minimum When connected to a controller and BOOST is selected at the controller the output...

Страница 24: ...24 Notes Maintenance Weekly...

Страница 25: ...25 Warning Relieve the pressure within the system by opening the pressure relief valve on the pool filter Notes...

Страница 26: ...26 AquaPure Ei Troubleshooting Sections references are for the installation manual...

Страница 27: ...27 AquaPure Ei Troubleshooting Sections references are for the installation manual...

Страница 28: ...28 AquaPure Ei Troubleshooting Sections references are for the installation manual Notes...

Страница 29: ...ER PCB ASSEMBLY APURE Ei REPLACEMENT KIT R0512300 CONTROL PCB ASSEMBLY APURE Ei REPLACEMENT KIT R0512400 COVER ASSEMBLY CONTROLLER APURE Ei REPLACEMENT KIT R0512500 OUTPUT CABLE ASSEMBLY APURE Ei REPL...

Страница 30: ...30 Replacement Parts and Exploded Views...

Страница 31: ...31...

Страница 32: ...32 AquaPure Ei Workbook 7 10 AquaPure Ei Workbook 7 10...