background image

 

VENTING INFORMATION 

 

 
B.  For Canopy-type commercial cooking hoods the inside edge thereof shall 

overhang or extend a horizontal distance of not less than six (6) inches 
beyond the edge of the cooking surface on all open sides, and the vertical 
distance between the lip of the hood and the cooking surface shall not 

exceed four (4) feet. 

   

 

 

 

 

 

 

 

 

In all cases, it is imperative to obtain the approval of the AHJ (Authority Having 
Jurisdiction).  This will typically be the mechanical inspection department of the 
local municipality’s building inspection division and/or the local fire marshal. 

 

 
C.  A grease duct serving a Type 1 Hood shall be constructed of at least 0.05

4

 

inch thick (No. 16 Manufacturer’s Standard Gauge

)

 

s

teel or at least 

0.04

3

 inch thick stainless steel 

(No. 18 MSG). D

uct enclosures for grease 

duct shall be constructed as the Building Code requires.  Duct 

enclosures shall be of at least one-hour fire-resistive construction in 

 

all

 

buildings and shall be of

 

2-hour fire-resistive construction in 

buildings with four or more stories.

      

 

1

 

Notes :
 1. Exhaust volume should be determined by the exhaust hood 
manufacturer based on their products listing and local code 
requirements. States such as California, Oregon, Washington,  and 
Connecticut all have code driven maximum exhaust volumes for specific 
equipment.   For example:  California mandates that solid fuel exhaust 
hoods for a wall mounted application can use NO MORE than 385 cfm/lf 
for solid fuel.
 2.

Spark arrestor type filters are required

 3.

Hoods serving solid fuel equipment must be dedicated to solid fuel 

only (no gas or electric) with their own dedicated fire protection system. 
   

A.  

Exhaust  h

oods   should   be  

 
 

Liste

d,  Type  1  hoods with automatic fire 

       suppression systems and

 conform to NFPA 96  

 

requirements

.  

 

 

D.    

E

xhaust 

hood 

volume 

should be  based 

on the specifications from the 

                   

        2

009

 (or later)

 International Mechanical Code Section 507.

Содержание Combo broiler

Страница 1: ... MANUFACTURING INC 972 285 4855 Texas 820 W Kearney Suite B 800 527 4831 All 50 States Canada P O Box 850522 972 289 0801 Parts Service Mesquite TX 75185 0522 972 288 9488 Fax OPERATIONS AND SERVICE MANUAL ...

Страница 2: ...SN _______________ ...

Страница 3: ...ire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector and chimney should be inspected at least twice monthly during the heating season to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire Exhaust Hood Required This unit MUST BE INST...

Страница 4: ......

Страница 5: ...WOOD SHOW BROILER OPERATIONS AND SERVICE MANUAL MANUFACTURED BY J R MANUFACTURING INC Rev 09 17 ...

Страница 6: ......

Страница 7: ...CONTENTS WOOD SOURCE 7 WARRANTY 6 WORDS OF CAUTION CLEANING AND ASH REMOVAL 4 VENTING INSTRUCTIONS 1 INSTALLATION 2 MAINTENANCE AND SUGGESTIONS 5 OPERATING PROCEDURES 3 ...

Страница 8: ......

Страница 9: ... requires Duct enclosures shall be of at least one hour fire resistive construction in all buildings and shall be of 2 hour fire resistive construction in buildings with four or more stories 1 Notes 1 Exhaust volume should be determined by the exhaust hood manufacturer based on their products listing and local code requirements States such as California Oregon Washington and Connecticut all have c...

Страница 10: ... and sides With no upper enclosure panels 48 With upper enclosure panels 2 Unit to be installed on a non combustible floor GRATES AND GRATE FRAME Remove all items packed inside the unit If your unit has a moveable cooking surface with lifting wheel carefully allign the cables on the wheel shaft while the grate frame is resting on the firebox floor with no grates installed Slowly turn the wheel to ...

Страница 11: ...g various products FOOD FIRE SPECIAL COOKING TIME Beef Steak 1 Well Done Slow Use Spatula not fork 15 to 20 minutes Beef Steak 1 Rare Hot Turn for marking 8 to 10 minutes Pork Spareribs Med Hot Watch Carefully 1 to 1 hours Chicken half Med Bone down 1st 20 min 45 to 50 minutes Chicken whole Med Breast up 1 to 1 hours Fish Firm Fleshed Med Hot Brush baste often 6 to 8 minutes Fajita thick Med Hot B...

Страница 12: ...ll as this might snap the cable or weaken it 4 Clean the grate surface after each use and grease well 5 Do not turn the product until it has been on the grill long enough to seal over otherwise the meat will stick to the surface 6 Do not allow hot ashes and coals to remain in contact with the grate frame or grate frame legs if your unit employs a grate frame with legs This will cause premature fai...

Страница 13: ... burning F Always test the doneness of your food Chicken must be checked at the thigh and leg joints for doneness A sharp fork inserted should let clear juices escape Fish should be flaky when tested or in the case of swordfish firm when pressed G Never try to grill fish thinner than one 1 inch in thickness as it will dry out rapidly Fish must be brushed often with olive oil lemon butter etc H By ...

Страница 14: ...ssible and to facilitate quick solutions to all problems that might arise with the lowest expense possible to the user s To help us achieve this goal please follow these procedures a problem Have ready the Model and Serial Number of your equipment 1 Telephone our service department at 972 289 0801 at the first sign of 3 Labor to remove replace or repair defects under this warranty must be authoriz...

Страница 15: ... Inc 201 N Beltline Road Irving TX 75061 Phone 972 986 6339 Fax 972 790 1176 www abfpinc com Serving the Dallas Ft Worth Metroplex s finest restaurants as well as throughout the U S and abroad since 1976 Cooking woods available Oak Pecan Hickory Mesquite For delivery Call 972 986 6339 1 7 ...

Страница 16: ......

Отзывы: