fore the clearing process is finished will result in a file error in the
counter.

DEFAULTS

NOTE:  The nonvolatile
memory in the TRAX I will re-
tain the default settings you
program. These settings will be
used for future traffic studies
without having to re-enter the DEFAULTS menu.

INTERVAL

Internally store data in 5, 10, 15, 30, or 60 minute
intervals. Use the TAB button to select INT and
press DO. Use TAB to highlight the number of
minutes in which you would like the data stored.
With the number flashing, press DO.

SPACE

Set the proper spacing for the tube layout you will
be using. Use the TAB button to select SPACE
and press DO. Use the keypad to enter your cor-
rect tube spacing. When finished, press DO.
NOTE: The spacing does not affect volume
studies and does not need to be changed for
volume only studies. We recommend leaving the
spacing set at 8 ft.

DATE

USA (month/day/year) or World (day/month/year)
formats.

UNITS

Select either English or Metric units.

DT/DTX

Dead time or D-Bounce for air switches. Use the
TAB button to select DT and press DO. Use the
keypad to enter in the DT and press DO when  com-
pleted. Typically, 25 ms is the normal setting. The
DTX setting should only be used for very low
speed counting. Refer to Chapter 7 for more in-
formation.

2-5

 INT  SPACE  DATE  UNITS
 DT DTX DBV VEH      EXIT

  Select time interval

 for Binned Data

Chapter 2 — Operation of the TRAX I

Содержание TRAX I

Страница 1: ...i...

Страница 2: ...he following number 215 491 4899 Monday Friday 8 00 AM to 5 00 PM Eastern time You may also contact us by fax at 215 491 4889 or via e mail at sales jamartech com Address any correspondence to JAMAR T...

Страница 3: ...in unless you are going to do a different type of study 7 From the Main Menu press the DO key when Count is flashing 8 Select the type of study you wish to do by using the TAB key and hitting DO when...

Страница 4: ...6 Tests 2 7 Count Menu 2 8 Basic 2 8 Volume Only 2 8 Per Vehicle 2 8 Binned 2 8 Tube Layout Selection 2 9 Site Code 2 10 Count Start up Menu 2 11 Stat 2 11 Set Times 2 11 Test 2 12 Start 2 13 Basic Da...

Страница 5: ...1 1 Chapter 1 Introduction to the TRAX I Chapter 1 Introduction to the TRAX I...

Страница 6: ...binned class speed and or gap data These vari ous modes allow you to go from a simple one lane volume count to a multi lane individual axle time stamped raw data collection with the same piece of equi...

Страница 7: ...p of the front panel is used to power the unit A four line by 20 character display helps you select the proper entries All options are clearly displayed with the currently selected option flashing The...

Страница 8: ...TRAX I User s Manual 1 4 This page was intentionally left blank...

Страница 9: ...Operation of the TRAX I 2 1 Chapter 2 Chapter 2 Operation of the TRAX I...

Страница 10: ...ter you power on the TRAX I the sign on screen is displayed This shows the version number of the firmware in the TRAX I in the lower right hand corner The second screen as shown below displays the tub...

Страница 11: ...UTILITIES Perform miscellaneous operations that include the option to download to a MODULE CLEAR the counter program the DEFAULT settings set the TIME DATE and perform diagnostic TESTS on the TRAX I...

Страница 12: ...o transport the module back to your office for downloading into the software STATUS This option allows you to check whether there is data currently stored in the module WRITE This option allows you to...

Страница 13: ...the TAB button to select SPACE and press DO Use the keypad to enter your cor rect tube spacing When finished press DO NOTE The spacing does not affect volume studies and does not need to be changed f...

Страница 14: ...et must be from sepa rate vehicles VEH The TRAX I has the ability to upload user defined tables for class speed or gap data collection from JAMAR s data analysis software The VEH op tion is used to re...

Страница 15: ...the TRAX I will display the key you pressed Press DO to exit SER PORT Plug a test connector into your serial port The connecter must short the 2 3 pins NOTE This test will fail if a test connector is...

Страница 16: ...nted as one After you select the type of study you want you will be taken to the tube layout selection menu de scribed on the following page Per Veh Short for Per Vehicle this study is one step below...

Страница 17: ...the options for the types of data that you want to collect press the TAB key until CONT is flashing Then press the DO key and you will be taken into the tube layout selection menu described below Tub...

Страница 18: ...ed collected there To enter a Site Code press DO while YES is flashing You may then enter a numerical code up to 12 characters using the numbered keys on the TRAX I If you do not wish to use a Site Co...

Страница 19: ...available screens you will be re turned to the Count Start up Menu Set Times IMPORTANT Although the ability to set start and stop times is provided as a con venience for some users we recommend using...

Страница 20: ...s will be shown on this screen as they pass over the tubes However this data is not being recorded in the memory of the TRAX I If you TAB through the status screens you will see in one of the screens...

Страница 21: ...is recorded in the appropriate channel The bottom line tells you what number count this study is CNT 02 the percentage of memory available MEM 95 and the battery voltage 6 4v The top two lines of thi...

Страница 22: ...e VOL UME and that the TRAX I is running or recording data RUN The next two lines represent the channels that data is being recorded on A and B As the tires from an axle strike the tubes an asterisk i...

Страница 23: ...le 33 MPH and how the vehicle struck the tubes A C The third line tells you the gap between vehicles GAP 21 and the length between the last two axles 14 2 NOTE If you are collecting data with a four r...

Страница 24: ...op line of this screen gives the date and time as they are set in the TRAX I The next two lines are used to tell you if start stop times have been programmed If they have been programmed you will see...

Страница 25: ...ent the tubes that data is being recorded on A B C D As the tires from an axle strike the tubes an asterisk is recorded in the appropriate channel The bottom line tells you what number count this stud...

Страница 26: ...ogrammed you will see the times and dates listed The last line is used to tell you what site code has been programmed for the study Ending a Count To end a count turn the TRAX I off The count will be...

Страница 27: ...3 1 Chapter 3 Road Tube Installation Chapter 3 Road Tube Installation...

Страница 28: ...wn to provide the best results based on extensive testing L1 L3 L4 L5 L6 L7 L9 L10 Long tube setups To encompass all types of vehicles and speeds a tube length of sixty 60 feet is recommended for roun...

Страница 29: ...e short tube should be in stalled to the zone line center of the highway Observe traffic to be sure that vehicles in the outer lane are not coming in contact with the short tube Installation Round Tub...

Страница 30: ...MASTIC 6 Lengths are satisfactory Mastic Clamp End Plate Chinese Finger or Figure 8 TRAX Clamp End Plate Chinese Finger or Figure 8 TUBE 60 ft lengths are recommended Coil any excess tube near the co...

Страница 31: ...tube This eliminates nailing the half tube on the center line which can create a safety problem for in stallation personnel Checking for Accuracy Once your tubes are installed and you are collecting...

Страница 32: ...TRAX I User s Manual 3 6 This page was intentionally left blank...

Страница 33: ...Chapter 4 Road Tube Layouts 4 1 Chapter 4 Road Tube Layouts...

Страница 34: ...tube the tube length from the end of the road to the counter must be the same for all tubes In all short tube long tube layouts the vehicle must strike the short tube first To collect class or speed...

Страница 35: ...hat are then later grouped into usable data by the software The diagrams for the following layouts assume a length of twelve feet per lane of traffic and are shown for round tube and mini tube L1 Two...

Страница 36: ...two feet apart EXAMPLE The TRAX I has been programmed to use the divide by two technique As a car approaches the tubes in the inner lane and both front and rear axles pass over the A and the B tube th...

Страница 37: ...a half inches apart EXAMPLE The TRAX I has been programmed to use the divide by two technique A car is traveling southbound approaching the tubes As the front and rear axles strike the A tube a one is...

Страница 38: ...ned Class Speed Gap One Direction In this layout both tubes A and B are extended across the lanes to be studied Channel A and channel B record dependent on each other The tubes should be spaced eight...

Страница 39: ...hould be spaced eight feet apart and be of equal length B A 24 ft TRAX I 36 ft Round 26 ft Mini 8 ft L7 Four Lanes A B C D Basic Volume This layout is the same as the L1 layout but with four tubes ove...

Страница 40: ...t spacing between tubes 36 ft Round 26 ft Mini 36 ft Round 26 ft Mini D C 12 ft 12 ft 24 ft 24 ft B A TRAX I L9 Four Lanes with Lane Separation A to B B to A C to D D to C Basic Volume This layout is...

Страница 41: ...as the L5 layout but with the addition of two half tubes A and C to provide lane separation Refer to the L5 layout for fur ther information This layout is for single direction traffic The A and C tub...

Страница 42: ...r to the L11 layout for further information The A and C tubes should be spaced eight feet apart as should the B and D tubes The A tube should be spaced six inches from the B tube and the C tube should...

Страница 43: ...Chapter 5 Downloading the TRAX I 5 1 Chapter 5 Downloading the TRAX I...

Страница 44: ...se your cable fits into a connector on your PC does not mean it is a serial port Consult your computer instruction manual if you have any questions on which ports are serial ports on your computer 2 M...

Страница 45: ...ost newer computers can download at 19200 or higher While the data is being downloaded the display on the TRAX I will show The computer will show the data being received in blocks Each block represent...

Страница 46: ...TRAX I User s Manual 5 4 This page was intentionally left blank...

Страница 47: ...Chapter 6 Battery Care 6 1 Chapter 6 Battery Care...

Страница 48: ...arge the battery to its highest potential normally from 6 4 volts and up The battery can be charged through the charge port with the TRAX I charger or a similar 6VDC charger with the correct plug and...

Страница 49: ...rosive Do not short circuit battery terminals Some batteries are protected with self resetting fuses but short circuits may still cause severe dam age to the battery It is normal for a battery to beco...

Страница 50: ...TRAX I User s Manual 6 4 This page was intentionally left blank...

Страница 51: ...Chapter 7 Low Speed Counting 7 1 Chapter 7 Low Speed Counting...

Страница 52: ...s on the road tube represents one count in the volume mode Additionally the TRAX I will record a count even if the front and rear tires on only one side of the vehicle passes over the tube as well as...

Страница 53: ...Chapter 8 Trouble shooting 8 1 Chapter 8 Troubleshooting...

Страница 54: ...the display comes up If the unit was in the field collecting data when this problem occurred turn the unit off return it to your office and charge Even if the battery voltage was too low to power the...

Страница 55: ...re set with the proper length spacing and perpen dicular to the flow of traffic One simple condition check of a tube that is laid out in the field is to disconnect the tube from the TRAX I and hold th...

Страница 56: ...TRAX I User s Manual 8 4 This page was intentionally left blank...

Страница 57: ...Chapter 9 Menu Tree Specifications 9 1 Chapter 9 Menu Tree Specifications...

Страница 58: ...TRAX I User s Manual 9 2 SIGN ON COUNT STATUS UTILITIES CLEAR DEFAULTS MOD TIME DATE BASIC VOL ONLY PER VEH BINNED TESTS STAT MENU TREE...

Страница 59: ...9 3 CONFIRM MEMORY DISPLAY KEYS SER PORT INT SPACE DATE UNITS DT DBV OPTIONS LAYOUTS SITE CODE START UP Chapter 9 Menu Tree Specifications...

Страница 60: ...ble lead gel battery with solar panel option Interface RS 232 serial 9 pin DBS socket Temperature Range Minus 40 F 40 C to 165 F 72 C Date Format USA or World Time Recording Intervals 5 10 15 30 or 60...

Страница 61: ...Appendix A 1 Appendix...

Страница 62: ...of vehicles which are pulling recreational or other light trailers are included Class 4 Buses This class includes all vehicles manufac tured as traditional passenger carrying buses with two ax les an...

Страница 63: ...ive or less axles consisting of three or more units in which the pulling unit is a tractor or single unit truck Class 12 Six Axle Multi Trailer Trucks This class includes all six axle vehicles consist...

Страница 64: ...ted before it leaves our facility However just like other complex elec tronic devices problems can occur We have always suggested that users verify the continuing accuracy of any device they use We fe...

Отзывы: