JALpower JP5530 Series Скачать руководство пользователя страница 3

JP5530 1-3KVA 

1

 

 

1.1 Description of Commonly Used Symbols 

      Some or all of the following symbols may be used in this manual and may appear in your application 

process. Therefore, all users should read the form carefully and thoroughly. 

 

Symbol & Description 

Symbol Description 

 

Caution, danger 

 

Danger electronic shock 

 

Alternating Current (AC) 

 

Direct Current (DC) 

 

Protective ground 

 

Do not dispose with ordinary trash 

 

1.2 Safety Notes   

 

1)  Read safety notes carefully and thoroughly before operation, to ensure use correctly 

and save this manual properly. 

2)  Please follow the alarm table and requirements on UPS when you operate it. 

3) 

Please don’t use UPS in case of overload.

 

4) 

Don’t open UPS by non-professionals since the danger of electricity which is raised by 

batteries.

 

5) 

Keep batteries away from fire, otherwise, they will be burned.

 

6) 

Don’t open or damage batteries, it is harmful to eyes, skin and so on.

 

7) 

Avoid short circuit of two poles on battery.

 

8) 

The air inlet port at the front panel and the outlet port on the rear panel and two side 

panels should not be blocked so as to ensure good ventilation.

 

9)  Life of UPS will be subject to the environment; don’t use UPS in the following 

environment:    

Too high or too low temperature (above 40

 or below 0

), high humidity (above 90%); 

Any place which is close to heating facilities or with shake and shock; 

A place with metal, cankerous, flammable articles around 

10) Please use dry powder fire extinguisher instead of liquid fire extinguisher in the event 

of fire.

Содержание JP5530 Series

Страница 1: ...USER S MANUAL JP5530 1 3KVA...

Страница 2: ...n 2 2 2 UPS Appearance 3 3 1 Unpacking Inspection 4 3 2 Installation notes 4 3 3 Cable connection 4 3 4 Connection communication cable 6 4 1 Introduction of display panel 8 4 2 Turn on Shut off UPS 10...

Страница 3: ...se of overload 4 Don t open UPS by non professionals since the danger of electricity which is raised by batteries 5 Keep batteries away from fire otherwise they will be burned 6 Don t open or damage b...

Страница 4: ...guration standard type and long backup time type each available in the following ratings 1KVA 2KVA and 3KVA Table2 1 UPS types and configurations UPS type JP5530 series JP5530 RM series Standard 1KVA...

Страница 5: ...JP5530 1 3KVA 3 2 2 UPS Appearance JP5530 1K rear panel JP5530 2 3K rear panel JP5530 1K rear panel JP5530 2K 3K rear panel Note Other standard output sockets are optional such as EU BS etc 16A 16A...

Страница 6: ...d not be titled The air inlet port at the front panel and the outlet port on the rear panel and two side panels should not be blocked so as to ensure good ventilation 3 2 3 In case if the UPS is unpac...

Страница 7: ...figuration please check whether the wires are securely affixed 4 Put back the terminal block cover to the rear panel 3 3 2 Operation procedure of external for long back up time UPS The battery connect...

Страница 8: ...same 3 4 Connection communication cable DB9 computer interface If use the software which is putted with UPS to monitor the UPS please just take out the USB or RS232 cable put the two sides of this cab...

Страница 9: ...JP5530 1 3KVA 7 SNMP card Realization of remote monitoring and management of UPS through Internet...

Страница 10: ...pply power to load via bypass it is orange 3 Battery indicator mains abnormal batteries provide power it is orange 4 Inverter indicator when inverter provides power to load it is green 5 Fault indicat...

Страница 11: ...ft to right side and the corresponding load capacity is increasing when the squares light one by one Battery capacity diagram is shown as below There are five black squares from left to right side and...

Страница 12: ...ns mode Press button for more than 1 second UPS will start At the same time UPS will make self checking all the indicators on the panel will turn on and power off one by one UPS goes to work normally...

Страница 13: ...ttery indicator will flash mains indicator power off battery will provide power to the load Battery mode In battery mode buzzer will beep every 4 seconds Shut off UPS Press button for more than 1 seco...

Страница 14: ...ng period charging is recommended at the intervals 3 months 5 1 4 Normally the battery should be charged and discharged every 4 to 6 months Charging should be begun after UPS shut down automatically i...

Страница 15: ...hould be no fault indication 5 2 2 Check the transfer between UPS operation modesDisconnect the main input to simulate a mains failure UPS should transfer to battery mode and operate normally then rec...

Страница 16: ...temperature F5 too high or too low BUS voltage F6 too high or too low inverter voltage F7 PFC fault F8 circulation negative work F9 not flow equalize F10 working power fault F11 inverter relay sticky...

Страница 17: ...e office 2 The AC mains is normal but the UPS has no input power The AC input over current protection switch at the rear panel of the power module cut off the mains input upon input over current fault...

Страница 18: ...JP5530 1 3KVA 16 7 1 Specification...

Отзывы: