background image

1

Safety

• This product must not be disassembled under any circumstances. Only

authorized repair technicians are qualified to conduct disassembly and repairs.

• Failure to heed this warning may result in fire, electrical shock or injury.

• Do not install this product in a refrigerated warehouse, heated swimming pool or

other location where temperature and humidity are significantly different. (Failure

to heed this warning may result in electrical shock or malfunctioning.)

• Do not install this product where it will be directly exposed to rain.

(Failure to heed this warning may result in electrical shock or malfunctioning.)

• Do not install this product in a location where acid, alkali or organic solvent

vapors, paints or other toxic gases, gases containing corrosive components or

high concentrations of oily smoke are present. (Failure to heed this warning may

result not only in malfunctioning but also fire, power leakage and electrical

shock.)

• Do not use this product outside the range of its rated voltage and control capacity. 

JRH73/700 ~ JRH73/5000 single phase (220-240V 50Hz); JRH73/6000 three phase 

(380-400V 50Hz). If electric heater is used JRH/700 ~ JRH73/6000 three phase 

(380-400V 50Hz).

(Failure to heed this warning may result in fire or electrical shock.)

• Install this product in an environment where the temperature ranges from -1

2

 °C

to +4

6

 °C and the relative humidity is less than 80%. If condensation is expected

 

to form, heat up the fresh outside air by a duct heater etc.

• Select a position for introducing the outside air where no exhaust or combustion

gases will be sucked into the fresh air duct and where it will not be covered by

snow (Failure to ensure a supply of air can result in producing a state of Oxygen

deficiency inside the room.)

• Select an adequately sturdy position for installing the product and install it

properly and securely. (Injury may result if the product should fall.)

• Use the designated electrical wires for the terminal board connections and

connect the wires securely so that they will not be disconnected. (Failure to

ensure proper connections may result in fire.)

• When passing metal ducts through wooden buildings clad with metal laths, wire

laths or metal, these ducts must be installed in such a way that they will not

make electrical contact with metal laths, wire laths or metal sheets.

(Power leakage can cause ignition.)

• The outside ducts must be tilted at a gradient(1/30 or more) downwards toward

the outdoor area from the main unit, and properly insulated. (The entry of rain

water may cause power leaks, fire or damage to household property.)

• Gloves should be worn during installation.

(Failure to heed this warning may result in injury.)

• A dedicated circuit breaker must be installed at the origin of mains power supply.

This circuit breaker must be provided with a means for locking (lock and key).

• Connect the product properly to the ground. 

(Malfunctioning or power leaks can cause electrical shock.)

• An isolator switch having a minimum contact gap of 3 mm in all poles must be

provided as a means of disconnecting the power supply.

Содержание JRH73 Series

Страница 1: ...JAKKA heat recovery units JRH73 Series User s Manual...

Страница 2: ...Contents Safety 1 Control List 2 Components 3 Dimensions 3 Installation 4 Maintenance 7 Technical specification 3 Troubleshooting 10...

Страница 3: ...he fresh outside air by a duct heater etc Select a position for introducing the outside air where no exhaust or combustion gases will be sucked into the fresh air duct and where it will not be covered...

Страница 4: ...re the drain hose is connected and check for any blockages through the drain line If needed clean it 06 Please check that the duct dimensions used in the duct system are correct and of the same dimens...

Страница 5: ...Power W 2x135 2x219 2x278 2x656 2x540 2x560 2x650 2x920 Maximum Current A 2x0 60 2x0 90 2x1 20 2x1 45 2x2 30 2x2 40 2x2 70 2x1 90 1 It is measured when external static pressure is 0 Pa 2 Sound level...

Страница 6: ...ut referring to the Installation and Operational Manual Check that the ground wire is securely connected Connect a fuse of specified capacity Do not install the unit remote controller and cable within...

Страница 7: ...t are made of ABS material hence do not need additional insulation After connecting the unit make sure that there is no leakage between the duct connections of the unit and the duct Use a duct tape wh...

Страница 8: ...Air Alternative Air Outlet Alternative Air Outlet Air Inlet Return Air or Outside Air Air Outlet Exhaust Air or Fresh Air Air Inlet Return Air or Outside Air Air Outlet Exhaust Air or Fresh Air Alter...

Страница 9: ...d junction of the ducts 2 Fit the ducts securely into the duct connection flanges and wind Aluminum tape to prevent air leakages 3 Suspend the ducts from the ceiling so that their weight will not be a...

Страница 10: ...Follow proper lockout tagout procedures to ensure the equipment cannot be inadvertently energized Secure drive sheaves to ensure rotor cannot freewheel Failure to secure drive sheaves or disconnect p...

Страница 11: ...factory set timer Remote controller informs the user to check the filters After the filters are cleaned by the user filter warning alarm must be reset NOTE It may be handy to keep spare clean and dry...

Страница 12: ...owder if need be Leave it to dry after cleaning and mount it to the unit after it is completely dry Tighten the service cover screws thoroughly and make sure the heat recovery exchanger does not fall...

Страница 13: ...Filters clogged or dirty a Change or clean filters b Air duct is clogged b Check the air ducts c Channel connections are incomplete c Check the duct system for leaks and complete the connections HIGH...