Troubleshooting

8

FAULT

REASON

SOLUTION

FANS DO NOT 

WORK

a.

Power supply off

a.

Turn on the power supply

b.

No signal from the

control panel

b.

Press the correct buttons of the

control panel

c.

Incorrect or loose

electrical connection

c.

Connect connections correctly

d.

Motors in thermal

protection mode

d.

Check motor current

FANS RETURN 

TO REVERSE 

DIRECTION

a.

Phase connection is

not correct

a.

Make the correct phase connection

LOW AIR FLOW

a

.

F

ilters clogged or

dirty

.

a.

Change or clean filters

b.

Air duct is clogged

b.

Check the air ducts

c.

Channel connections

are incomplete.

c.

Check the duct system for leaks and

complete the connections

HIGH AIR FLOW

a

.

Channel connections

are incomplete.

a.

Check the duct system for leaks and

complete the connections

b.

Supply voltage is low

b.

Measure the current drawn by the

motor against overloading

c.

Grilles are not

mounted

c.

Mount the grilles

d.

Filters are not

mounted

d.

Mount the filters

DRAINAGE 

WATER

CAN NOT BE

DISCHARGED

a

.

Drainage plugged

a.

Clean drain pipe

b.

Incorrect installation

of drainage pipe.

b.

Mount the drain pipe correctly

Содержание JRH73 Series

Страница 1: ...JAKKA heat recovery units JRH73 Series User s Manual...

Страница 2: ...Contents Safety 1 Control List 2 Components 3 Dimensions 3 Installation 4 Maintenance 7 Technical specification 3 Troubleshooting 10...

Страница 3: ...he fresh outside air by a duct heater etc Select a position for introducing the outside air where no exhaust or combustion gases will be sucked into the fresh air duct and where it will not be covered...

Страница 4: ...re the drain hose is connected and check for any blockages through the drain line If needed clean it 06 Please check that the duct dimensions used in the duct system are correct and of the same dimens...

Страница 5: ...Power W 2x135 2x219 2x278 2x656 2x540 2x560 2x650 2x920 Maximum Current A 2x0 60 2x0 90 2x1 20 2x1 45 2x2 30 2x2 40 2x2 70 2x1 90 1 It is measured when external static pressure is 0 Pa 2 Sound level...

Страница 6: ...ut referring to the Installation and Operational Manual Check that the ground wire is securely connected Connect a fuse of specified capacity Do not install the unit remote controller and cable within...

Страница 7: ...t are made of ABS material hence do not need additional insulation After connecting the unit make sure that there is no leakage between the duct connections of the unit and the duct Use a duct tape wh...

Страница 8: ...Air Alternative Air Outlet Alternative Air Outlet Air Inlet Return Air or Outside Air Air Outlet Exhaust Air or Fresh Air Air Inlet Return Air or Outside Air Air Outlet Exhaust Air or Fresh Air Alter...

Страница 9: ...d junction of the ducts 2 Fit the ducts securely into the duct connection flanges and wind Aluminum tape to prevent air leakages 3 Suspend the ducts from the ceiling so that their weight will not be a...

Страница 10: ...Follow proper lockout tagout procedures to ensure the equipment cannot be inadvertently energized Secure drive sheaves to ensure rotor cannot freewheel Failure to secure drive sheaves or disconnect p...

Страница 11: ...factory set timer Remote controller informs the user to check the filters After the filters are cleaned by the user filter warning alarm must be reset NOTE It may be handy to keep spare clean and dry...

Страница 12: ...owder if need be Leave it to dry after cleaning and mount it to the unit after it is completely dry Tighten the service cover screws thoroughly and make sure the heat recovery exchanger does not fall...

Страница 13: ...Filters clogged or dirty a Change or clean filters b Air duct is clogged b Check the air ducts c Channel connections are incomplete c Check the duct system for leaks and complete the connections HIGH...

Страница 14: ...For Troubleshouting Please Contact Boulevard Zoran Djindjic 80 11070 Novi Beograd Tel 381 11 2600 901 Fax 381 11 2600 906 www jakkagroup com jakkagroup jakkagroup com...

Отзывы: