Operation 31
TM-6740GE Series
3.10
External HD Locking and External VD Reset
Table 6
External HD Locking and External VD Reset (eA to eE)
Scan Mode
Pixel
Horizontal
External HD Locking Timing (Pixels)
Binning
Scan Freq.
Time
eA eB eC eD eE
Area Clock (kHz)
(
μ
sec)
No binning
A
40MHz
100
10
<20ns
400
32
368
13
B 100
10
400
368
C 250
4
160
128
D 250
4
160
128
1x2
A 100
10
400
368
B 100
10
400
368
C 25ns 250
4
160
128
D 250
4
160
128
1x4
A 92.6
10.8
432
400
B 92.6
10.8
432
400
C 208.3
4.8
192
160
D 208.3
4.8
192
160
2x1
A
20MHz
100
10
<20ns
200
26
184 12
B 100
10
200
184 12
C 250
4
80
64 11
D 250
4
80
64 11
2x2
A 100
10
200
184 12
B 100
10
200
184 12
C 50ns 250
4
80
64 11
D 250
4
80
64 11
2x4
A 92.6
10.8
216
200 12
B 92.6
10.8
216
200 12
C 208.3
4.8
96
80 11
D 208.3
4.8
96
80 11
4x1
A
10MHz
100
10
<20ns
100
16
84
15
B 100
10
100
84
C 250
4
40
24
D 250
4
40
24
4x2
A 100
10
100
84
B 100
10
100
84
C 100ns 250
4
40
24
D 250
4
40
24
4x4
A 92.6
10.8
108
92
B 92.6
10.8
108
92
C 208.3
4.8
48
32
D 208.3
4.8
48
32
Содержание TM-6740GE
Страница 2: ......
Страница 15: ...Installation 15 TM 6740GE Series Figure 4 Back Focus Set Screw Locations...
Страница 26: ...TM 6740GE Series 26 Operation 3 8 Camera Timing Charts...
Страница 27: ...Operation 27 TM 6740GE Series...
Страница 28: ...TM 6740GE Series 28 Operation...
Страница 34: ......
Страница 70: ...TM 6740GE Series 70 Appendix...
Страница 71: ......