GevSCPHostPort
ー
ー
Controls the port of the selected channel to which a GVSP transmitter must send data stream or
the port from which a GVSP receiver may receive data stream. Setting this value to 0 closes the
stream channel.
GevSCPSFireTestPacket
True, False
False
Sends a test packet. When this feature is set, the device will fire one test packet.
GevSCPSDoNotFragment
True, False
False
The state of this feature is copied into the "do not fragment" bit of IP header of each stream
packet. It can be used by the application to prevent IP fragmentation of packets on the stream
channel.
GevSCPSPacketSize (B)
576〜16366
1476
Set the packet size.
GevSCPD
0〜4294967295
0
Controls the delay (in GEV timestamp counter unit) to insert between each packet for this
stream channel.
GevSCDA
ー
ー
Controls the destination IP address of the selected stream channel to which a GVSP transmitter
must send data stream or the destination IP address from which a GVSP receiver may receive
data stream.
GevSCSP
ー
ー
Indicates the source port of the stream channel.
Setting range
Default value
Description
Configure pulse generator settings.
1〜4096
165
Set the division value for the prescaler (12 bit) using PixelClock as the base
clock.
0.0181274〜74.25
0.45
Set the clock used for the pulse generator.
This value is calculated using the [ClockPreScaler] value as a base.
PulseGenerator0,
PulseGenerator1,
PulseGenerator2,
PulseGenerator3
PulseGenerator0
Select the pulse generator.
PulseGeneratorLengthValue
1〜1048575
30000
Set the maximum count-up value as a clock count.
PulseGeneratorLength (ms)
ー
ー
Set the maximum count-up value in milliseconds.
This value is calculated using the [PulseGeneratorLength] value as a base.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorFrequency (Hz)
PulseGeneratorClock (MHz) ÷
1048575 x 1000000 〜
PulseGeneratorClock (MHz) x
1000000
ー
Set the maximum count-up value as a frequency.
This value is calculated using the
[PulseGeneratorLength] value as a base.
PulseGeneratorStartPointValue
0〜1048575
0
Set the start point of the High interval as a clock count. When the counter
reaches this value, the output will be 1.
PulseGeneratorStartPoint (ms)
0〜42949.6
0
Set the start point of the High interval in milliseconds.
When the counter reaches this value, the output will be 1.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorEndPointValue
1 〜 1048575
15000
Set the start point of the Low interval as a clock count. When the counter
reaches this value, the output will be 0.
PulseGeneratorEndPoint (ms)
0〜42949.6
0.15
Set the start point of the Low interval in milliseconds.
When the counter reaches this value, the output will be 0.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorPulseWidth (ms)
ー
0.15
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is calculated. The setting
range varies depending on the [ClockPreScaler] value.
PulseGeneratorRepeatCount
0 〜 255
0
Set the repeat count for the counter. When this is set to [0], a free counter is
enabled with no repeat limit.
PulseGeneratorClearActivation
Off,
LevelHigh,
LevelLow,
RisingEdge,
FallingEdge
Off
Set the clear signal condition for the count clear input of the pulse generator.
PulseGeneratorClearSource
Exposure Active,
LVAL,
Pulse Generator[0 - 3],
UserOutput0, UserOutput1,
UserOutput2, UserOutput3,
Line4 TTL In 1,
Line5 Opt IN 1,
Line10 TTL In 2,
Line13 TTL In 3,
Logic Block 0, Logic Block 1,
Encoder Trigger
Low
Select the count clear input signal source.
PulseGeneratorClearSyncMode
AsyncMode, SyncMode AsyncMode
Select the sync mode for the count clear input signal.
p) PulseGenerator
Item
PulseGeneratorSelector
PulseGeneratorClock (MHz)
ClockPreScaler
SW-4000T-10GE
—
55
—
Содержание SW-4000T-10GE
Страница 60: ...SW 4000T 10GE 60 Spectral Response Wave length nm Relative Response Wave length nm ...
Страница 61: ...SW 4000T 10GE 61 Dimensions F mount SW 4000T 10GE F Dimenstional tolerance 0 3mm Unit mm ...
Страница 62: ...SW 4000T 10GE 62 M52 mount SW 4000T 10GE M52 Dimenstional tolerance 0 3mm Unit mm ...