Setting range
Default value
Description
Configure counter settings. (This camera only supports counter functions.)
Counter0
Counter1
Counter2
Counter3
Counter4
Counter5
ー
Select the counter.
Counter Event Source
Counter0
Off, Line Trigger
Counter1
Off, Line Start
Counter2
Off, Exposure Start
Counter3
Off, Frame Trigger
Counter4
Off, Frame Start
Counter5
Off, Frame Transfer End
Off
Assign the counter event signal for which you want to read the count value
to a dedicated counter, and read the value.
Counter Event Activation
ー
ー
Set the count timing.
The setting value is fixed with the following data.
Counter0 Rising Edge
Counter1 Rising Edge
Counter2 Rising Edge
Counter3 Rising Edge
Counter4 Rising Edge
Counter5 Falling Edge
Counter Reset
ー
ー
Reset the counter.
Counter Value
0〜65535
0
Display the count value.
Counter Status
ー
ー
Display the counter status.
Counter Idle: Idle
Counter Active: Counting
Counter Overflow: Count value exceeded the mazimum value.
Setting range
Default value
Description
Configure settings for encoder control.
Off,
Line4 TTL In 1,
Line5 Opt In 1,
Line10 TTL In 2,
Line13 TTL In 3
Off
Select where to input the signal from the rotary encoder.
Off,
Line4 TTL In 1,
Line5 Opt In 1,
Line10 TTL In 2,
Line13 TTL In 3
Off
Select where to input the signal from the rotary encoder.
1 〜 4294967295
65536
Set the number of triggers to be generated during one pitch of the rotary
encoder. The number of triggers is 65536 / (set value).
none, 2pulse,
4pulse, 8pulse,
16pulse, 32pulse
none
When the reliability of the interval of the signal output from the rotary
encoder is low.
(Some signal interval is extremely long or short).
When this function is enabled, internal processing is performed by averaging
the interval of several previous signals.
0 〜 150 (10 step)
0
Apply a low-pass filter to prevent noise on the signal from the rotary encoder
and stabilize the signal for the specified number of cycles.
1 〜 2550
10
Set the strobe length of the Trigger signal generated from the rotary encoder
by the number of cycles
Counter Selector
i) EncoderControl
EncoderSourceA
EncoderDivider
Encoder Filter (ns)
EncoderStrobe (ns)
Item
EncoderSourceB
Item
Encoder Averaging Interval
h) Counter And Timer Control