SW-4000Q-SFP
— 36 —
EEN (Exposure Enable) Function
Perform external output for the timing at which video is accumulated to the sensor.
The signal is output to the DC IN / TRIG IN connector (12-pin round) or AUX connector.
Example: Output to DC IN/TRIG IN connector (12-pin round)
Trigger
Exposure
EEN
( Internal / External )
Test Pattern Function
You can display the following types of test patterns (Off, White, GrayPattern1, GrayPattern2,
ColorBar). Video output is not possible while a test pattern is being executed. This function is
not dependent on gain and offset values that have already been configured.
◇
This function cannot be saved as the initial state of the camera.
Electronic Shutter
When you use this function, you can set the exposure to a preconfigured accumulation time,
regardless of the line rate.
• Variable range: 3 μs to 15.149 ms
• Variable unit: 0.01 μs (1clk)
• Supported operation modes: When Trigger Mode ON, Exposure Mode Timed
◇
You can also save the setting and have it applied whenever the power is subsequently
turned on, but this requires additional operations.
In “Trigger Mode OFF, Exposure Mode Timed” mode, the line rate configured will be the
maximum value at which the shutter operates. However, in “Trigger Mode ON, Exposure Mode
Timed” mode, the input trigger period will be the maximum value.
Caution