SW-2001Q-CL
34
Transmit the following to have a command list:
HP?<CR><LF>
The camera answers:
A list with all commands and possible settings
Invalid parameters send to camera: (99 is an invalid parameter)
SH=99<CR><LF>
The camera answers:
02 Bad Parameters!!<CR><LF>
To see firmware number.
VN?<CR><LF>
To see camera ID. It shows the manufacturing lot number.
ID?<CR><LF>
8.2. Command list
Command
Name
Format
Parameter
Remarks
A – General settings and useful commands.
EB Echo Back
EB=[Param.]<CR><LF>
EB?<CR><LF>
0=Echo off, 1=Echo on
Returns character
sent to the camera.
Off at power up
ST Camera Status
Request
ST?<CR><LF>
Display current
settings of all
functions
HP Online Help
Request
HP?<CR><LF>
Get a list of available
commands
VN
Firmware
Program
Version
Request
VN?<CR><LF>
3 digits
Example:
100 = Version 1.00
PV
FPGA Program
Version
Request
PV?<CR><LF>
3 digits
Example:
100 = Version 1.00
ID Camera ID
Request
ID?<CR><LF>
Returns the camera’s
ID (?). Factory
setting.
MD Model Name
Request
MD?<CR><LF>
Returns the camera’s
model name. Factory
setting.
UD User ID
UD=[Param.]<CR><LF>
UD?<CR><LF>
User definable field.
Up to 16 characters.
B - Line Rate, Exposure
LR Line Rate
LR=[Param.]<CR><LF>
LR?<CR><LF>
No-Shutter Mode:
2100 to 2150400 clocks
Shutter Select Mode:
2150 to 2150400 clocks
, in 25ns increments
Only valid for TG=0
AR One-push auto
line rate set
AR=[Param.]<CR><LF>
AR?<CR><LF>
0=Activate one-push auto line
rate set
Only valid for TR=0
and TG=0