SP-5000M-CXP4 / SP-5000C-CXP4
- 57 -
1) When the camera is powered
2) When the lens is selected in P-Iris Lens Select
3) If the lens is changed in P-Iris Lens Select
8.8.2.4 P-Iris Auto min. / P-Iris Auto max.
This function can set the control range when the iris is operated automatically. Auto max. sets the
limit when the iris goes open and Auto min. sets the limit when the iris goes closed. Auto max. can
be set to fully open but Auto min. is stopped at F5.6 as lens performance typically degrades if the
iris is closed beyond this point.
8.8.2.5 Auto iris Lens Control Signal output
If an auto iris lens is used, this parameter should be ON. This is the same for all available lenses.
8.8.3 Motorized lenses
The SP-5000C-CXP4 and SP-5000C-CXP4 can use the 3-axis motorized lens control for zoom, focus
and iris. The following functions are available via the motorized lens commands.
8.7.3.1 Iris
Open: While this command is supplied, the iris will continue to open.
Close: While this command is supplied, the iris will continue to close.
Stop: When this command is supplied, the iris operation stops.
8.8.3.2 Zoom
Wide: While this command is supplied, the zoom will continue to move towards wide
angle.
Tele: While this command is supplied, the zoom will continue to move towards telephoto.
Stop: When this command is supplied, the zoom operation stops.
8.8.3.3 Focus
Near: While this command is supplied, the focus will continue to shift closer to the
camera.
Far: While this command is supplied, the focus will continue to move towards infinity.
Stop: When this command is supplied, the focus operation stops.
8.8.4 Associated GenICam registers
GenICam
Name
Access
Values
Category
Lens Select
R/W
None
PIris Lens
Motor Lens
JAI-Custom
PIris Step Max
R/W
0 to 255
JAI-Custom
PIris Position
R/W
0 to 73
JAI-Custom
PIris Lens Select
R/W
LM16JC5MM
LM35JC5MM
JAI-Custom
PIris Auto Min
R/W
F_OPEN
F_14
F_20
F_28
F_40
JAI-Custom