Table - 11 Pulse Generator default settings
5.4.1 Clock Pre-scaler
Clock pre-scaler (Divide Value) can set the dividing value of the frequency divider (12-bit
length) and the pixel clock is used for this. Four built-in pulse generators work by the same
clock. In the SP-5000-CXP4, the clock is set at 86.4 MHz.
5.4.2 Pulse Generator Selector
This is where you select one of the 4 pulse generators in order to set or modify its parameters.
Table - 12
Pulse Generator setting
Fig.7
Pulse Generator pulse construction
Pulse generator
length
Pulse generator Start point
Pulse generator End point
Pulse generator repeat count = N
(Pulse generator length x N)
Pulse generator
Clear source IN
(Clear activation
= Rising edge
Clear SYNC mode
= Async)
Pulse generator
Output
Pulse generator
length
Pulse generator
length
0
0
0
Display Name
Value
Clock Pre-scaler
1
Pulse Generator
Selector
Pulse Generator
Length
Start
Point
End
Point
Repeat
Count
Clear
Source
Clear
Inverter
Clear
Activation
Clear
Sync
Mode
-
Pulse Generator 0
1
0
1
0
Off
True
Off
Async Mode
-
Pulse Generator 1
1
0
1
0
Off
True
Off
Async Mode
-
Pulse Generator 2
1
0
1
0
Off
True
Off
Async Mode
-
Pulse Generator 3
1
0
1
0
Off
True
Off
Async Mode
Note:
When Pulse Generator Repeat Count is set to “0”, the camera is operating in free-running mode.
However, based on the above default setting, Length=1, Start Point=0 and End Point=1, Pulse Generator stops at
High output. Therefore, if Start Point=0 and End Point=1 are configured, Length should be
“
2
”
as the minimum
active width.
Trigger Selector
item
Description
Pulse Generator 0
If Pulse Generator 0 is selected, Length Start Point
、
End Point
、
Repeat Count
、
Clear Source
、
Clear
Inverter Clear Activation and Clear Sync Mode of pulse generator 0 are displayed under the selector.
Pulse Generator 1
If Pulse Generator 1 is selected, Length Start Point
、
End Point
、
Repeat Count
、
Clear Source
、
Clear
Inverter Clear Activation and Clear Sync Mode of pulse generator 1 are displayed under the selector.
Pulse Generator 2
If Pulse Generator 2 is selected, Length Start Point
、
End Point
、
Repeat Count
、
Clear Source
、
Clear
Inverter Clear Activation and Clear Sync Mode of pulse generator 2 are displayed under the selector.
Pulse Generator 3
If Pulse Generator 3 is selected, Length Start Point
、
End Point
、
Repeat Count
、
Clear Source
、
Clear
Inverter Clear Activation and Clear Sync Mode of pulse generator 3 are displayed under the selector.