SP-5000M-CXP4 / SP-5000C-CXP4
- 35 -
7.3.4 Associated GenICam registers
GenICam
Name
Access
Values
Category
Trigger
Selector
R/W
Acquisition Start
Acquisition End
Frame Start
Acquisition Control
Trigger
Mode
R/W
On
Off
Acquisition Control
Trigger
Software
W
Command
Acquisition Control
Trigger
Source
R/W
Low
High
Software Trigger
Frame Trigger Wait
Frame Active
Exposure Active
FVAL
PG0 to PG3
User out 0 to 3
TTL 1 in
Opt 1 in
CXP in (Trigger Packet)
Nand 0 to 1
Acquisition Control
Trigger
Activation
R/W
Rising Edge
Falling Edge
Level High
Level Low
Acquisition Control
Trigger
Over Lap
R/W
Off
Read out
Acquisition Control
7.4. Normal continuous operation (Timed Exposure Mode/Trigger Mode OFF)
This is used for applications which do not require triggering. In this mode, the video signal for the
auto-iris lens is available if AUX connector is configured with option Type 2.
The frame rate of full pixels readout is 253.8 fps.
Primary settings to use this mode
Trigger Mode: Off