AnalogAll : 0dB 〜 24dB
DigitalRed : -7dB 〜 15dB
DigitalBlue : -7dB 〜 15dB
Off, Continuous, Once
DigitalRed, DigitalBlue : -7dB 〜 15dB
Off, Continuous, Once,
Preset4000K, Preset4600K, Preset5600K, Preset6500K,
Preset7500K
16 (4 x 4) Area
3000K 〜 9000K
Detect white blemishes using threshhold values
(100 steps available)
(black blemish correction performed only at factory)
Interpolation using adjacent pixels
(continuous blemishes not corrected)
3183 pixels
Can be adjusted automatically together with AGC and ASC
0.45、0.5、0.55、0.6、0.65、0.75、0.8、0.9、1.0
(9 steps available)
OFF︓γ= 1.0、ON = 257 points can be set
10G(20 Hz 〜 200 Hz X-Y-Z direction)
80G
Input range
DC + 10 V 〜+ 25 V(Via input terminal)
Consumption
12.5 W(typ.)
( at 12 V input, default setting, 25 ℃ environment )
16.8 W(max.)
F-mount, M42-mount
F-mount 46.5mm, tolerance 0 mm 〜 0.05 mm
M42-mount 45.5mm, tolerance 0 mm 〜 0.05 mm
IR cut filter (SP-45000C-CXP4 only)
5℃〜+ 45℃ / 20%〜 80%(non-condensing)
25℃〜+ 60℃ / 20%〜 80%(non-condensing)
CE(EN61000-6-2 and EN61000-6-3), FCC part 15 class B,
RoHS, WEEE, KC
62 × 62 × 84.2 mm(W×H×D)
(excluding mount protrusions)
330g(F-mount) / 340g(M42-mount)
Power supply
Dimensions (housing)
Weight
Verified performance temperature / humidity
Storage temperature / humidity
Regulations
Lents mount
Flange back
Optical filter
12-pin connector
LUT
Vibration resistance
Impact resistance
ALC
Gamma
Blemish
correction
Detection
Correction
Correctable pixels
White balance
WhiteBalanceGain
BalanceWhiteAuto
Photometry area
Adjustment range
Manual adjustment range
Gain
adjustment
adjustment Auto gain
—
64
—
SP-45000M-CXP4/SP-45000C-CXP4
Package contentsCamera
body (1)
Sensor protection cap (1)
Dear Customer (sheet) (1)
Optional accessories (not supplied)
MP-42 tripod mount
Design and specifications are subject to change without notice.
Approximately 30 minutes of warm-up are required to achieve these specifications.
About the verified performance temperature, make sure the following temperature
condition is met when operating the unit.
1) The camera's internal temperature sensor detects temperatures of 98.8°C or
less during operation.
If the above temperature conditions are exceeded, take measures to dissipate heat
according to your installation environment and conditions.
Caution
Содержание SP-45000C-CXP4
Страница 66: ... 66 Dimensions SP 45000M CXP4 SP 45000C CXP4 M42 mount F mount Dimensional tolerance 0 3mm Unit mm ...
Страница 67: ...M42 mount 67 SP 45000M CXP4 SP 45000C CXP4 Dimensional tolerance 0 3mm Unit mm ...
Страница 71: ... 71 Revision Date Changes Revision history SP 45000M CXP4 SP 45000C CXP4 ...