PulseGeneratorClearSource
Low
High
AcquisitiionTriggerWait
AcquisitionActive
FrameTriggerWait
FrameActive
ExposureActive
FVAL
LVAL
PulseGenerator0
PulseGenerator1
PulseGenerator2
PulseGenerator3
UserOutput0
UserOutput1
UserOutput2
UserOutput3
Line5 - OptIn1
Line6 - OptIn2
NAND0Out
NAND1Out
Action1
Low
Select the count clear input signal source.
PulseGeneratorClearInverter
True, False
False
Select whether to invert the polarity of the
count clear input signal.
PulseGeneratorClearSyncMode AsyncMode, SyncMode AsyncMode
Select the sync mode for the count clear
input signal.
Configure JAI ALC settings. These settings
are also used for AGC (auto gain control).
30~95
50
Set the target level for ALC. (unit: %)
Low Right,
Low Mid-Right,
Low Mid-Left,
Low Left,
Mid-Low Right,
Mid-Low Mid-Right,
Mid-Low Mid-Left,
Mid-Low Left,
Mid-High Right,
Mid-High Mid-Right,
Mid-High Mid-Left,
Mid-High Left,
High Right,
High Mid-Right,
High Mid-Left,
High Left
Low Right
Select the area for which to configure
[ALCAreaEnable].
ALCAreaEnable
True, False
True
Enable/disable the photometry area
selected in [ALCAreaSelector].
True, False
True
True: Operate ALC with all areas
designated as photometry areas,
regardless of the individual
enabled/disabled photometry area
states configured in
[ALCAreaSelector].
False: Operate ALC according to the
individual enabled/disabled
photometry area states configured
in [ALCAreaSelector].
100 ~
100
Set the minimum value for the
ExposureAuto(ASC) control range.
ALCAreaSelector
ALCReference
q) JAICustomControlALC
AutoShutterControlExposureMin
ALCAreaEnableAll
SP-12401M-PGE/SP-12401C-PGE
—