CounterEventSource
Counter0
Off, FrameTrigger
Counter1
Off, ExposureStart
Counter2
Off, SensorReadOut
Counter3
Off, FrameTransferEnd
Off
Assign the counter event signal for which
you want to read the count value to a
dedicated counter, and read the value.
CounterEventActivation
ー
ー
Set the count timing.
The setting value is fixed with the following
data.
Counter0 RisingEdge
Counter1 RisingEdge
Counter2 RisingEdge
Counter3 FallingEdge
CounterReset
ー
ー
Reset the counter.
CounterRefresh
0~65535
0
Update the count value.
CounterValue
0~65535
0
Display the count value.
CounterStatus
ー
ー
Display the counter status.
CounterIdle: Idle
CounterActive: Counting
CounterOverflow: Count value exceeded the
mazimum value
Configure settings for action control.
0x00000000~
0xFFFFFFFF
ー
An action command is executed if this
ActionDeviceKey matches the DeviceKey
contained in the action command message.
1,2
1
select the ActionSelector.
ActionGroupMask
0x00000000~
0xFFFFFFFF
ー
An action command is executed if the
result of an AND operation of GroupMask
contained in this ActionGroupMask and an
action command message is not 0.
ActionGroupKey
0x00000000~
0xFFFFFFFF
ー
An action command is executed if this
ActionGroupKey matches the GroupKey
contained in the action command message.
Configure settings for event control.
AcquisitionTrigger,
FrameStart,
FrameEnd,
FVALStart,
FVALEnd,
ExposureStartRed,
ExposureEndRed,
Line1-TTLOut1-RisingEdge,
Line1-TTLOut1-FallingEdge,
Line2-OptOut1-RisingEdge,
Line2-OptOut1-FallingEdge,
Line5-OptIn1-RisingEdge,
Line5-OptIn1-FallingEdge,
Line6-OptIn2-RisingEdge,
Line6-OptIn2-FallingEdge
AcquisitionTrigger
Select the event to send the event
message.
EventNotification
On, Off
Off
Sets whether or not to send an event
message when an event selected by
[EventSelector] occurs.
i) ActionControl
j) EventControl
EventSelector
ActionDeviceKey
ActionSelector
SP-12401M-PGE/SP-12401C-PGE
— 5
7
—