③ POWER/TRIG LED
Indicates the power and trigger input status.
LED status and camera status
LED
Light
Status
POWER/
TRIG LED
(Lit amber)
Camera initializing.
(Lit green)
Camera in operation.
(Blinking green)
During operation in trigger mode, trigger signals are
being input.
❖ The blinking interval is not related to the actual input interval of
the external trigger.
SP-12401M-PGE/SP-12401C-PGE
④ ACT LED
Indicates the GigE network status.
⑤ LINK LED
Indicates whether the GigE network connection is established or not.
⑥ DC IN/TRIG connector(12-pin round)
Connect the cable for a power supply (optional) or for DC IN / trigger IN here.
HR10A-10R-12PB(71)(Hirose Electric or equivalent)
Pin No.
Input/Output
Signal
Description
1
GND
2
Power In DC In
DC 12 V ~ 24 V ± 10%
3
In
Opto In 2 -
Line 6
4
In
Opto In 2 +
5
In
Opto In 1 -
Line 5
6
In
Opto In 1 +
7
Out
Opto Out 1 - Line 2
8
Out
Opto Out 1 +
9
Out
TTL Out 1
Line 1
10
11
Power In DC In
DC 12 V ~ 24 V ± 10%
12
GND
Note
When DC power is supplied to either Pin 1/Pin 2 or Pin 11/Pin 12, the camera
operates.
—
8
—