Configuring the Camera
51
RM/TM-1327GE Series
Category / Feature
Read/
Write
Value Range
Default Value
Visibility
Level
AcquisitionRecordingWrapAr
ound
RW False
True
False
Expert
BlockBufferCount
RO
Depends on image size.
Expert
BlockBufferCurrentIndex WO
0 to (BlockBufferCount – 1)
Expert
AcquisitionRecordingWrapAr
ound
RW False
True
False
Expert
ExposureMode
RW
Off
ContinuousProgrammable
AsyncNoShutter
PulseWidthControl
AsyncProgrammable
Off
Beginner
AsyncProgrammable RW
0-2079
Factory Set
Beginner
ContinousProgrammable RW
0
- 1052
Factory Set
Beginner
TriggerPolarity RW
ActiveLow
ActiveHigh
ActiveLow Beginner
AnalogControls
GainRaw RW
71
- 231
Factory Set
Beginner
VTopr RW
128
- 224
Factory Set
Guru
VBottom RW
120
- 255
Factory Set
Guru
AutoBlackLevel RW
Enable
Disable
Disable
Guru
CountersAndTimersControls
TimerSelector RW
Timer1
Timer2
Timer3
Timer4
Timer1
Beginner
TimerDelayRaw RW
1-65535
1024
Beginner
TimerDurationRaw RW
1-65535
4096
Beginner
TimerGranularityFactor RW
1-65535
0
Beginner
TimerTriggerActivation RW
RisingEdge
LevelHigh
FallingEdge
AnyEdge
LevelLow
RisingEdge Beginner
TimerTriggerSource RW
PLC_Q
Continuous
PLC_Q
Beginner
CounterSelector RW
Counter1
Counter1 Beginner
Содержание RM/TM-1327GE Series
Страница 2: ......
Страница 21: ...Operation 21 RM TM 1327GE Series 3 7 Camera Timing Charts ...
Страница 60: ......