Apart from the standard continuous operation, the RM-67X features three external asynchronous trigger modes (edge pre-
select, pulse width controlled and Async RESET).
3.1
Input of Ext HD/VD Signals
In the default setting the camera will accept external HD/VD signals on pin 13 and 14 of the 15 pin connector. If external
HD/VD is applied, the camera will synchronize to it. If no external sync signals are applied, the camera will operate with its
internal x-tal controlled sync. The time requirements to the relation between VD and HD are shown in Fig. 6.
To use this mode:
Input:
Ext. VD in or int. VD out on pin 14 on 15 pin connector.
Ext. HD in or int. HD out on pin 13 on 15 pin connector.
Note: External sync system should follow the camera scanning system.
3.1.1
External Sync
The RM-67X can accept external sync from an external sync generator or frame grabber. Input specifications:
Internal/External auto switch
fH+15.734 KHz ± 5%, fV +50.00 Hz ± 5%
Min signal amplitude 3.5 Vp-p
Note: The RM-67X has a one (1) horizontal line delay between the input VD signal and the output video. If
external vertical drive (VD) is applied to the camera, it may cause the video output to be delayed 1 HD
(1 H = ~64.0 µ s). If the imaging system is capable of automatically detecting the start of video (within a
few HD), then no problem will exist. Otherwise, reconfigure the video capturing sequence to delay video
acquisition of 1H.
Figure 6.
Input Signals
Содержание RM-670
Страница 2: ......
Страница 10: ...RM 67X Series x List of Tables List of Tables Table 1 RM 67X Product Specifications Table 43 ...
Страница 13: ...Hardware Introduction 13 RM 67X Series Figure 1 RM 67X System Configuration ...
Страница 17: ...Hardware Installation 17 RM 67X Series Figure 5 15P 02 9P FULL Cable ...
Страница 40: ...RM 67X Series 40 Functional Options ...
Страница 80: ...RM 67X Series 80 Appendix ...
Страница 81: ......