RM/TM-4200GE Series
60
Configuring the Camera
Category / Feature
Read/
Write Value Range
Default Value
Visibility
Level
ExposureMode
RW
Off
ContinuousPreset1
…
ContinuousPreset9
ContinuousProgrammable
AsyncNoShutter
AsyncPreset1
…
AsyncPreset8
PulseWidthControl
FixedExposurePIV
PWC_PIV
AsyncProgrammable
Off
Beginner
AsyncProgrammable RW
0-2079
Factory Set
Beginner
ContinousProgrammable RW
ScanMode
Limited
0 - 2079 (A)
0 - 1100 (B)
0 - 600 (C)
0 - 400 (D)
0 - 2079 (UserProgramble)
0 - 1050 (Binning 2x2)
0 - 650 (RPDZoom)
Factory Set
Beginner
TriggerPolarity RW
ActiveLow
ActiveHigh
ActiveLow
Beginner
AnalogControls
GainSelector RW
All
Tap2
All
Beginner
GainRaw RW
0
- 4095
Factory Set
Beginner
GainAutoBalance RW
Off
Once
Off
Beginner
BlackLevelSelector RW
All
Tap2
All
Expert
BlackLevelRaw RW
0
- 4095
Factory Set
Expert
BlackLevelAutoBalance RW
Off
Continuous
Continuous
Expert
CountersAndTimersControls
TimerSelector RW
Timer1
Timer2
Timer3
Timer4
Timer1
Beginner
TimerDelayRaw RW
1-65535
1024
Beginner
TimerDurationRaw RW
1-65535
4096
Beginner
TimerGranularityFactor RW
1-65535
0
Beginner
TimerTriggerActivation
RW RisingEdge
LevelHigh
FallingEdge
AnyEdge
LevelLow
RisingEdge
Beginner