— 29 —
GO-5101M-PMCL / GO-5101C-PMCL
Exposure Mode
The following exposure modes are available on the camera.
Exposure Mode
Description
Off
Exposure control is not performed (free-running operation).
Timed
Mode in which control is performed using exposure time. Acquire images using an
exposure time configured beforehand on an external trigger.
Trigger Width
Mode in which control of the exposure time is performed using the pulse width of the
trigger input signal. The exposure time will be the same as the pulse width of the
trigger input signal. This allows long exposure.
The settings for exposure control and triggers are related to each other. Be sure to configure the settings
described in “Configuring Exposure and External Trigger Settings” (page 17).
Image Output Timing
■
Vertical timing
Tap
Geometry
CL
PixelClock
[MHz]
H
Frequency
(KHz)
FVAL
BlankingLine
[A]
FVALValid
Line [B]
Total
FrameLine [C]
Total Frame
Period (msec)
Frame Rate
(Hz)
1X2-1Y
(Full)
37.125
30.036
34
2056
2090
69.6
14.37
74.25
60.073
34
2056
2090
34.8
28.74
84.85
68.433
34
2056
2090
30.5
32.74
1X3-1Y
(Full)
37.125
44.946
34
2056
2090
46.5
21.51
74.25
74.548
34
2056
2090
28.0
35.67
1X4-1Y
(Full)
37.125
59.879
34
2056
2090
34.9
28.65
74.25
74.548
34
2056
2090
28.0
35.67