![JAI GO-5101C-PMCL Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/jai/go-5101c-pmcl/go-5101c-pmcl_user-manual_631474044.webp)
— 44 —
GO-5101M-PMCL / GO-5101C-PMCL
■
Internal camera blocks
Frametrigger
Event
detection
Counter
At event occurrence or count up
Counter
Counter
Counter
Counter reset
Internal MCU of camera
Read requested
counter value
Send
information
to the HOST
Event
detection
Event
detection
Event
detection
Exposure Start
Frame Start
FrameTransfer End
■
To use the counter function
Configure the settings as follows.
Three counters can be configured (Counter 0 to 2).
Item
Setting value / selectable range
Description
Counter 0 to 2
Counter 0 to 2
Select the counter.
Counter 0 to 2 Event Source
Off,
Frame Trigger,
Frame Start,
Exposure Start,
Frame Transfer End
Select the counter event signal for
which to read the count value.
Counter 0 to 2 Event Activation
Rising Edge (fixed)
or Falling Edge
Specify the timing at which to count.
Note
The four counter event signals are always counted up internally on the camera.