[Sequencer LUT Mode] defines whether Gamma or LUT is to be applied to the sequence. If Gamma
is selected, the Gamma setting defined in the camera’s Analog Control section will be applied to all
exposures in the sequence. If LUT is selected, the LUT characteristics defined in Analog Control will
be applied to any index where [Sequencer LUT enable] has been set to ON.
[Reset Sequencer Index] causes the index selector to be reset to Index 1. Thus, the sequencer pattern
will start over at the next trigger.
In Trigger Sequencer mode, patterns always begin with Index1. Subsequent triggers follow the user-
defined values in [Sequencer Index Frame Count] and [Sequencer ROI Next Index].
Assigning a Next Index value of “1” to an index creates a loop back to the start of the sequencer
pattern. Setting a Next Index value to “OFF” causes the value of [Sequencer Repetition] to be applied
as described below.
[Sequencer Repetition]
This parameter applies to Trigger Sequencer patterns which include an index whose [Sequencer ROI
Next Index] is set to OFF.
When the index whose [Sequencer ROI Next Index] is set to OFF is finished executing, the value of
Sequencer Repetition (range = 1-255) is decremented internally. If the result of the decrement is not
zero, the Trigger Sequencer pattern starts over from Index1. If the result of the decrement is zero, the
status changes to Acquisition Stop and external triggers are not accepted.
Trigger Sequencer example
User-defined Indexes (up to 128)
Index1
Index2
Index4
Index3
ROI
Exposure
Gain
LUT
Binning
Frame Count = 2
Next Index = 3
ROI
Exposure
Gain
LUT
Binning
Frame Count = 1
Next Index = 1
ROI
Exposure
Gain
LUT
Binning
Frame Count = 1
Next Index = 4
ROI
Exposure
Gain
LUT
Binning
Frame Count = 2
Next Index = 2
1
2
6
3
4
5
Triggers /
Image
Frames
Index structure for Trigger Sequencer
Index1
ROI1
Exposure
1
Gain1
(M/Red/Blue)
Black
Level1
Binning1
(H/V)
LUT
Enable1
Frame
Count1
Next
Index1
Index2
ROI2
Exposure
2
Gain2
(M/Red/Blue)
Black
Level2
Binning2
(H/V)
LUT
Enable2
Frame
Count2
Next
Index2
Index128
ROI128 Exposure
128
Gain128
(M/Red/Blue)
Black
Level128
Binning128
(H/V)
LUT
Enable128
Frame
Count128
Next
Index128
Index
Selector
(MUX)
Index Table
・
Index Next Index
Current
Index
Command
・
Reset Sequencer Index
Reset
Sequencer
Common Settings
・
Sequencer LUT mode
Command Sequencer mode
This mode allows the user to vary the “pattern” of the sequence in response to external factors.
Changes in the sequence can be initiated manually or in a programmatic fashion as the result of data
from sensors/controllers or from the analysis of previous images.