— 20 —
GO-5100M-PGE / GO-5100C-PGE
Control Without External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Item
Setting value / selectable range
Trigger Selector (trigger operation)
Frame Start
Trigger Mode
Off
Exposure Mode
Timed (control via exposure time)
Exposure Time
8 bit: 14 to 7999812 (µs)*
1
10-/12-bit: 27 to 7999631 (µs)*
1
Exposure Auto
Off, Continuous
*1 The maximum value for [Exposure Time] varies depending on the value configured for the [Acquisition Frame
Rate Raw] setting.
Max. value for [Exposure Time] = [Acquisition Frame Rate Raw] value - 188 µs (8-bit) or 369 µs (10-/12-bit)
The minimum value will differ depending on the [Pixel Format] setting value.
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Specify the exposure time in [Exposure Time].
The setting value for the exposure time can only be changed when [Exposure Auto] is set to [Off].
If [Exposure Auto] is set to [Continuous], temporarily set it to [Off] before changing the exposure
time.
3
Set [Trigger Mode] to [On].
4
If necessary, change the [Exposure Auto] setting.
When not Controlling the Exposure Time
Configure the settings as follows.
Item
Setting value / selectable range
Exposure Mode
Off
The exposure will be performed with an exposure time equal to 1 / frame rate.