— 53 —
GO-2401M-PGE / GO-2401C-PGE
Item
Setting range
Default value
Description
h) Digital IO Control
Configure settings for digital input/output.
Line Selector
Line2 - Opt Out 1,
Line3 - Opt Out 2,
Line5 - Opt In 1,
Time Stamp Reset,
NAND Gate 0 In 1,
NAND Gate 0 In 2,
NAND Gate 1 In 1,
NAND Gate 1 In 2
Line2 - Opt Out 1 Select the input/output to configure.
Line Mode
—
Output
Display the input/output status (whether it
is input or output).
Line Inverter
True, False
False
Enable/disable polarity inversion for the
selected input signal or output signal.
Line Status
—
True
Display the status of the input signal or
output signal (True: High, False: Low).
LineSource
Low, High,
Acquisition Trigger Wait,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL,
User Output 0,
User Output 1,
Line 5 - Opt In 1,
Pulse Generator 0,
Nand 0 Out, Nand 1 Out
Low
Select the line source signal for the item
selected in [Line Selector].
Source Format
—
Opto Coupled
Display the current I/F type.
User Output Selector
User Output 0,
User Output 1
User Output 0
Set the user output signal.
User Output Value
True, False
False
i) Pulse Generators
Configure pulse generator settings.
Clock Pre-scaler
1 to 4096
165
Set the division value for the prescaler
using the pixel clock as the base clock.
Pulse Generator Clock (MHz)
0.018127 to 74.25
0.45
Set the clock value (MHz) for the pulse
generator.