Item
Setting range
Default value
Description
n) JAI Custom Control ALC
Configure JAI ALC settings. These
settings are also used for AGC (auto gain
control).
ALC Reference
10 to 100
50
Set the target level for ALC. (unit: %)
ALC Area Selector
Low Right to High Left
Low Right
Select an ALC metering area.
ALC Area Enable
True, False
False
Enable/disable the metering area where
selected metering area.
ALC Area Enable All
0 to 1
1
Set whether to enable ALC for all areas.
ASC Min.
73 to 7999899
100
Set the minimum value for the ASC range.
ASC Max.
74 to 7999900
8000000
Set the maximum value for the ASC
range.
AGC Min.
100 to 1599
100
Set the minimum value for the AGC
range.
AGC Max.
101 to 1600
1600
Set the maximum value for the AGC
range.
AGC/ASC Control Speed
1 to 8
4
Set the reaction speed for AGC/ASC.
These settings are also used for auto
exposure control.
o) JAI Custom Control Blemish
Configure settings for JAI white blemish
correction.
Blemish Enable
True, False
True
Set whether to enable white blemish
correction.
Blemish Detect
—
—
Detect white blemishes.
Blemish Detect Threshold
0 to 100
10
Set the white blemish detection threshold.
Blemish Detect Position Index
0 to 255
0
Select the index table for the white
blemish detection position.
Blemish Detect Position X
–1 to 1935
–1
Set the horizontal position.
Blemish Detect Position Y
–1 to 1215
–1
Set the vertical position.
p) JAI Custom Control Shading
Configure shading correction settings.
Shading Correction Mode
GO-2401M-PGE:
Flat Shading (fixed)
GO-2401C-PGE:
Flat Shading, Color
Shading
Flat Shading
Select the shading correction mode.
Shading Mode
Off, User 1, User 2, User 3
Off
Select whether to use shading correction.
When using the function, select the user
area to which to save the shading
correction value.
Perform Shading Calibration
—
—
Execute shading correction. After
execution, the shading correction value is
automatically saved to the selected user
area.
Shading Detect Result
—
—
Display the shading detection results.
q) JAI Custom Control MultiROI
When using the JAI Multi ROI function, set
the scanning area.
Multi Roi Index
Index 1 to 5
Index 1
Set the Multi ROI index table.
Multi Roi Width
16 to 1936/16 steps
1936
Set the width. When binning is enabled
on the GO-2401M-PGE, the maximum
value will change.
Multi Roi Height
GO-2401M-PGE:
1 to 1216/1 step
GO-2401C-PGE:
2 to 1216/2 steps
1216
Set the height. When binning is enabled
on the GO-2401M-PGE, the maximum
value will change.
Multi Roi Offset X
0 to 1920/16 steps
❖
maximum value
= 1936 - width value
0
Set the horizontal position. When binning
is enabled on the GO-2401M-PGE, the
maximum value will change.
Multi Roi Offset Y
GO-2401M-PGE:
0 to 1215/1 step
GO-2401C-PGE:
0 to 1214/2 step
❖
maximum value
= 1216 - height value
0
Set the vertical position. When binning is
enabled on the GO-2401M-PGE, the
maximum value will change.
Multi Roi Index Max
1 to 5
1
Set the Multi ROI index count.