64
̶
GO-2400M-PMCL / GO-2400C-PMCL
Function name
Access
type
Setting range
Min. value
Max. value
Default value
Description
ALC Area
Selector
R/W
LowRight [Low Right]
LowMidRight [Low Mid-Right]
LowMidLeft [Low Mid-Left]
LowLeft [Low Left]
MidLowRight [Mid-Low Right]
MidLowMidRight [Mid-Low
Mid-Right]
MidLowMidLeft [Mid-Low Mid-Left]
MidLowLeft [Mid-Low Left]
MidHighRight [Mid-High Right]
MidHighMidRight [Mid-High
Mid-Right]
MidHighMidLeft [Mid-High
Mid-Left]
MidHighLeft [Mid-High Left]
HighRight [High Right]
HighMidRight [High Mid-Right]
HighMidLeft [High Mid-Left]
HighLeft [High Left]
—
—
Low Right
Select the area for
which to configure
[ALC Area Enable].
ALC Area Enable R/W
Off
On
—
—
FALSE
Enable/disable the
photometry area
selected in [ALC Area
Selector].
ALC Area Enable
All
R/W
Off
On
—
—
On
On: Specify all
photometry areas for
ALC, regardless of
the enabled/disabled
statuses configured
individually for each
photometry area with
[ALC Area Selector].
Off: Specify areas for
ALC based on the
enabled/disabled
statuses configured
individually for each
photometry area with
[ALC Area Selector].
ASC Min.
R/W
100 to 7999999
100
7999999
100
Set the minimum
value for the
Exposure Auto (ASC)
control range.
ASC Max.
R/W
101 to 8000000
101
8000000
8216
Set the maximum
value for the
Exposure Auto (ASC)
control range.
AGC Min.
R/W
100 to 1599
100
1599
100
Set the minimum
value for the Gain
Auto (AGC) control
range.
AGC Max.
R/W
101 to 1600
101
1600
1600
Set the maximum
value for the Gain
Auto (AGC) control
range.
AGC/ASC
Control Speed
R/W
1(slow) to 8(fast)
1
8
4
Set the control speed
for AGC and ASC (8
is the fastest).
ALC Status
R/W
Off
AIC
ASC
AGC
—
—
—
Display whether ASC
or AGC is being
controlled during
ALC.