40
̶
GO-2400M-PMCL / GO-2400C-PMCL
For color
Master
Master
Gain
setting
value
Gain
amplification
Gain setting
value (scaling)
Gain adjustment range (Bayer color)
X89.12
X16
X7.15
X5.62
X1
X0.45
1600
0
37876 (X5.62)
0 (X1)
–4533 (X0.45)
R&B
Red
Blue
39dB
-7dB
0dB
24dB
15dB
0dB
–7dB
15dB
0dB
–7dB
15dB
37876 (X5.62)
0 (X1)
–4533 (X0.45)
LUT (Lookup Table)
The LUT function is used to generate a non-linear mapping between signal values captured on the
sensor and those that are output from the camera. You can specify the output curve using 256 setting
points (indexes) on the GO-2400M/C-PMCL.
■
To use the LUT function
Configure the settings as follows.
Item
Setting value / selectable
range
Description
JAI LUT Mode
LUT
Use LUT.
LUT Selector
*
R, G, B
Select the LUT channel to control.
LUT Index
GO-2400M-PMCL: 0 to 255
GO-2400C-PMCL: 0 to 255
Select the LUT index to configure. Indexes represent the
setting points, and values from the lowest point (Index 0) to
the highest point (Index 15) are represented. On the
2400M-PMCL, for example, Index 0 is full black and Index
255 is full white.
LUT Value
0 to 4095
Set the LUT output value for the selected index.
* GO-2400C-PMCL only
Note
For the GO-2400C-PMCL, the same characteristic curve is configured for R, G, and B.