EL-2800M-PMCL / EL-2800C-PMCL
- 66 -
2.4.8 LUT Control
Name
Interface
Acce
ss
Short
ASCII
Values
MIN
MAX
DEFAUL
T
Description
LUTValueRed
I Integer
R/W
LUTR
Param 1: LUT index
Param 2:LUTdata(Min
~
Max)
(Bayer model only)
0
4095
γ
=1
相当値
LUT*=[Param1],[Para
m2]<CR><LF>
LUT*?[Param1]<CR><
LF>
LUTValueGreen
I Integer
R/W
LUTG
Param 1: LUT index
Param 2:LUTdata(Min
~
Max)
0
4095
LUTValueBlue
I Integer
R/W
LUTB
Param 1: LUT index
Param 2:LUTdata(Min
~
Max)
(Bayer model only)
0
4095
2.4.9 Transport Layer Control
Name
Interface
Acce
ss
Short
ASCII
Values
MIN
MAX
DEFAUL
T
Description
DeviceTapGeome
try
I
Enumerat
ion
R/(W
)
TAGM
0: Geometry_1X_1Y
1: Geometry_1X2_1Y
3: Geometry_1X_2YE
6: Geometry_1X2_2YE
0
6
6
TAGM
=[Param.]<CR><
LF>
TAGM?<CR><LF>
2.4.10 User Set Control
Name
Interface
Access
Short
ASCII
Values
MIN
MAX
DEFAULT
Description
UserSetLoad
I Command
(R)/W
LD
0: Default
1: UserSet1
2: UserSet2
3: UserSet3
0
3
0
LD
=[Param.]<CR><LF>
LD?<CR><LF>
UserSetSave
I Command
(R)/W
SA
1: UserSet1
2: UserSet2
3: UserSet3
1
3
1
SA
=[Param.]<CR><LF>
SA?<CR><LF>