CV-A10 CL and CV-A70 CL
5. Pin Assignment
5.1. 12-pin Multi-connector (DC-IN/Trigger)
Type: HR10A-10R-12PB-01
(Hirose) male.
(Seen from rear of camera.)
Notes:
*1) See “7.1. Switch Settings” for more information.
Pin no.
Signal
Remarks
1
GND
2
+12 V DC input
3
GND
4
Iris video
Only Contin. and RCT mode. TR=0, TR=10
5
GND
6
HD input/
RxD in
SW301.2 ON for HD in.
OFF for RxD
. *1)
7
VD input/
TxD out
SW301.3 ON for VD in.
OFF for TxD
. *1) *2)
8
GND
9
XEEN out
Low during exposure
10
Trigger in
TI=1. Or Camera Link (TI=0). *1)
11
Reserved
12
GND
3
4
5
6
7
8
9
10
11
12
1
2
*2) Do not input ext. VD in trigger modes
.
Factory settings in
bold italic.
Fig. 2. 12-pin connector.
5.2. Digital Output Connector for Camera Link
Type: 26 pin MRD connector
13
14
1
26
3M 10226-1A10JL
Fig. 3. Camera Link connector
The digital output signals follow the Camera Link standardized multiplexed signal output
interface. Camera Link base configuration is used. The interface circuit is build around the NS
type DS90CR285MTD.
The following signals are found on the Digital Output Connector:
SerTC
RxD serial data to camera
(SW301.1.
On for CL
. Off 12 pin HR)
SerTFG
TxD serial data to frame grabber
(SW301.1.
On for CL
. Off 12 pin HR)
CC1
Trigger
input
(TI=0 for CL. TI=1 for 12 pin HR)
CC2
Factory
use
X0 to X3
Camera Link multiplexed data out
Xclk
Camera Link clock. Used as pixel clock.
In the Channel Link X0 to X3 multiplexed signals the following signals are encoded.
D0 – D9
8/10 bit video data out.
LVAL
Line VALid. Video line data is valid. High for valid line.
FVAL
Frame VALid. Video frame data is valid. High for valid frame.
DVAL
Data VALid. Effective video pixel data is valid. High for valid data.
EEN
Exposure ENable. High during exposure.
The polarity is positive and TRIG in negative as factory setting.
For Camera Link interface principle diagram please check Fig. 8.
- 4 -