CV-A10 CL and CV-A70 CL
LED for power and trigger.
On the camera rear a Light Emitter Diode is found. The light will be green when power is
connected. For trigger pulse input an amber flash will be seen.
Mode and function matrix for CV-A10CL and A70CL.
The following table shows which functions will work in the different modes.
Func.
Shutter
SM=
Part. s
SC=
Binning
VB= HB=
Smearl
SL=
Accum
LS=
Ext sync
Iris
video
Mode
TR=
0
1
2
*)
VD HD
out
Remarks
Cont.
0
√
√
√
√
√
√
- -
√
√
√
EPS
1
√
√
-
√
√
√
√
√
-
√
-
PWC
2
- - -
√
√
√
√
√
-
√
-
RTC
10
√
√
√
√
√
√
√
√
√
√
√
SG
3
- - - - - - -
-
√
√
-
√
= ok, - = no function.
*) Binning only for CV-A10 CL
The pixel clock is not changed in horizontal binning modes
.
V binning has priority over partial scan.
Horizontal binning will work with partial scan.
6.6. Request Functions.
The following commands are for identification and help.
Fig. 35. shows some printout examples from a PC running terminal emulator software. (Hyper
terminal). Status, version, camera ID, model name, user ID and the help list are shown.
Please refer to chapter 7.2. RS-232C control and chapter 7.3. CV-A10CL/A70CL Command List.
Echo Back
.
EB=1.
If on, the camera will echo back the RS-232C transmission.
Status
.
ST.
If received, the camera will send back its current setting for all functions.
Help
.
HP.
If received, the camera will send back a help list for all functions.
Version Number
.
VN.
If received, the camera will send back its firmware version number as a 3 digits number.
Camera ID.
ID.
If received, the camera will send back its ID, which is a manufacturing code.
Model Name.
MD.
If received, the camera will send back its model name.
User ID.
UD.
With this command, the user can program and store up to 16 characters for identification.
RS232C Baud Rate
. BDRT=1 through 4.
It is possible to change the communication speed from 9600 Baud to a higher speed. The new
selected speed will be effective after next power up.
- 24 -