LVAL_async timing
Fig.17. Pulse Width trigger mode. LVAL asynchronous
6.3.4.
EPS with Smear Less trigger mode
In this mode, a fast dump of accumulated charges is activated after the trigger pulse is input.
Then, the exposure starts at 64 L after the trigger leading edge.
The exposure time is determined by the presser shutter speed, either presser or
programmable.
Thus, as the fast dump is made, this mode functions as the smear less mode which eliminates
the smear on the upper part of the image.
Important notes on using this mode
When the shutter setting is either PE=511 or OFF, EEN is kept as HIGH.
Fig. 18. EPS with Smear Less
LVAL
ASYNC
3μ s± 1μ s
2L(min)
TRIG
1L
EEN
FVAL
FULL: 6L
~
7.1L(97.44us
~
115.3us)
Vbinnig:4L
~
5.2L(80.28us
~
104.36us)
In case the trigger pulse is input during FVAL being LOW,
LVAL async accumulation is initiated.
Exposure
CCD Exposure
TRIG
1.0231 ms
(63L)
EEN
FVAL
DVAL
FULL: 6L
~
7.1L(97.44us
~
115.30us)
Vbinni ng:4L
~
5.2L(80.27us
~
104.35us)
CCD Exposure