CM-030PMCL-RH
20
6.3.3.
Pulse Width Trigger Mode
In this mode the accumulation time is equal the trigger pulse width. Here it is possible to
have long time exposure. The maximum recommended time is <240 frames ( 2 seconds).
For timing details, refer to fig. 8 through fig. 13 and fig. 16 & 17.
To use this mode:
Set function:
Trigger mode to “Pulse width control”.
TR=2
Partial scan
SC=0 to 4
Vertical binning
VB= 0 or 1
Other functions and settings
Input:
Ext. trigger. Camera Link or 12-pin Hirose
TI=0, TI=1
Important notes on using this mode
1.
The minimum trigger interval > 1 LVAL
2.
Depending on the timing of the leading edge of the trigger pulse in relationship to
FVAL, accumulation will be synchronous or a-synchronous in relationship to LVAL. See
chapter 6.1.5. for details.
LVAL_sync timing
Fig. 16. Pulse width trigger mode. LVAL synchronized.
LVAL
SYNC
TRIG
TRIG
LVAL
1L( max)
1L
EEN
FVAL
FULL: 6L
~
7.1L(97.44us
~
115.3us)
Vbinnig:4L
~
5.2L(80.28us
~
104.36us)
In case the trigger pulse is input during FVAL being HIGH,
LVAL sync accumulation is initiated.
Exposure
CCD Exposure
Raising prohibited
2L(min)