Display rupture
Display encounters hard objects or sudden force, no replacement.
3.
Display a black screen
If the display surface temperature is too high, please note whether there is heater
nearby, if so please remove.
4.
Display ER0
If internal sensor is abnormal, please pay attention to whether the small black dot in
temperature sensing window damaged during removal.
5.
Display ER1
The system is set in the dual temperature control (ALL) mode, or it is not connected
with an external sensor, or the external sensor is abnormal.
6.
No pen on LCD
Please check whether the iron plate is deformation when installation.
If it is deformation, please correct it.
7.
No backlight
Please check backlight cable is pulled off the panel was removed.
8.
Backlight always bright
•
It is set bL is ON in the system menu
•
It is damaged, please replace it.
9. Large deviation of measurement temperature and the actual temperature
The thermostat should be installed at ventilated place.
It cannot be installed at the place in direct sunshine or nearby the heater
Back connection screw is not locked, causing terminal serious fever.
10.
Display 0 degrees
When the thermostat of the working environment temperature below the detection
0 degrees, that display 0 degrees.
The above is some of the most common errors, if you can’t solve, please contact the