background image

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. 

TSTATCCPQ501

   PROGRAMMABLE

D I G I T A L    T H E R M O S T A T

USER INFORMATION MANUAL FOR THE OPERATION AND 
MAINTENANCE OF YOUR NEW THERMOSTAT

Heating & Cooling 

72

72

I2:00

SET

AM

Tu

SINGLE STAGE HEAT & COOL

THERMOSTAT

5+2 DAY PROGRAMMABLE

Meets California Title 24 Residential

next

run

off

set

prog

5+2 DAY PROGRAMMABLE 
DIGITAL THERMOSTAT

Separate programs for 
weekdays & weekends
Large, easy to read, 
backlit digital display 
Installation Flexibility
    Batteries required for 
     4-wire operation
     No batteries needed 
     for 5-wire operation 

Содержание 5+2 DAY PROGRAMMABLEDIGITAL THERMOSTAT

Страница 1: ...NEW THERMOSTAT Heating Cooling 7272 I2 00 SET AM Tu SINGLE STAGE HEAT COOL THERMOSTAT 5 2 DAY PROGRAMMABLE Meets California Title 24 Residential next run off set prog 5 2 DAY PROGRAMMABLE DIGITAL THERMOSTAT Separate programs for weekdays weekends Large easy to read backlit digital display Installation Flexibility Batteries required for 4 wire operation No batteries needed for 5 wire operation ...

Страница 2: ...nual Thermostat Operation Time Period Operation CLOCK SET ADVANCED SETUP Page 1 3 4 5 6 PROGRAMMING Setup Overview Program Setup 7 SAFETY WARNINGS 2 BATTERY REPLACEMENT WARRANTY 8 9 16 18 19 Carrier Corporation Residential Light Commercial Systems Patents Pending 4 03 ...

Страница 3: ...eries may still be installed but are not required When is displayed the batteries must be replaced immediately The manufacturer cannot be liable for improper operation of the thermostat if the batteries are not immediately replaced The annual battery replacement is especially critical in locations subject to freezing temperatures The thermostat will be unable to turn on the Heat if the batteries a...

Страница 4: ...am OFF SET program NEXT BUTTON For programming For programming How to Use The Next button is used to advance from one step to the next in the programming and advanced setup screens of the thermostat pages 8 16 It is also used to enter the Advanced Setup screens page 16 The Heat Cool indicator will only energize if the thermostat is system powered next run off set prog ...

Страница 5: ...s SaSu represent the 2 weekend days Heat and Cool indicators In normal operation Heat or Cool appears reflecting the mode switch position Clock Display Desired Set temperature indicator Current room temperature indicator Time period indicators These indicate the part of the program that is currently active if the program switch is positioned to Run ...

Страница 6: ...e fan switched to auto In fan auto the fan will turn on only with a heat or cool demand When Fan On is selected the fan will run continuously Adjust the desired set temperature with the Up or Down buttons On or Auto Program Switch RUN OFF SET PROGRAM SWITCH MODE SWITCH FAN SWITCH Heat next run off set prog UP DOWN BUTTONS Heat Cool or Off ...

Страница 7: ... In fan auto the fan will turn on only with a heat or cool demand When Fan On is selected the fan will run continuously Optionally adjust the desired set temperature for temporary override The programmed settings will restore in the following time period On or Auto FAN SWITCH Program Switch RUN OFF SET PROGRAM SWITCH Heat next run off set prog UP DOWN BUTTONS Heat Cool or Off ...

Страница 8: ...ent day Su Slide the program switch to the SET position 6 00 PM Pushing and holding the Up or Down buttons will slew the time by 10s of minutes Press the NEXT button for 5 seconds to enter advanced setup Page16 Setting the time day are the first 2 steps after sliding the program switch to SET Program RUN OFF SET ...

Страница 9: ...ontinue the steps above until programming is complete Slide the program switch to RUN and the thermostat will now run the time period programming If the program switch is in the OFF position the thermostat will not run the time period program In this case the thermostat will be a manual heat or cool only thermostat Please be certain to program each time period in chronological order to ensure prop...

Страница 10: ...tons to adjust the start time for the morning time period 78 6 00 SET AM MTuWThF Cool Morning NEXT Use these buttons to adjust the cool setpoint for the morning time period 70 6 00 SET AM MTuWThF Heat Morning NEXT Use these buttons to adjust the heat setpoint for the morning time period 8 00 AM MTuWThF Use these buttons to adjust the start time for the day time period Day NEXT Weekday Programming ...

Страница 11: ...NEXT 62 8 00 SET AM MTuWThF Heat Use these buttons to adjust the heat setpoint for the day time period Day NEXT 6 00 PM MTuWThF Use these buttons to adjust the start time for the evening time period Evening NEXT 78 6 00 SET MTuWThF Cool Use these buttons to adjust the cool setpoint for the evening time period Evening PM NEXT Weekday Programming ...

Страница 12: ... PM NEXT MTuWThF Use these buttons to adjust the start time for the night time period Night I0 00 PM NEXT 82 SET MTuWThF Cool Use these buttons to adjust the cool setpoint for the night time period Night I0 00 PM NEXT 62 SET MTuWThF Heat Use these buttons to adjust the heat setpoint for the night time period Night I0 00 PM NEXT Weekday Programming ...

Страница 13: ...EXT 78 SET SaSu Cool Use these buttons to adjust the cool setpoint for the morning time period 6 00 Morning AM NEXT 70 6 00 SET AM SaSu Heat Morning Use these buttons to adjust the heat setpoint for the morning time period NEXT 8 00 AM Day SaSu Use these buttons to adjust the start time for the day time period NEXT Weekend Programming ...

Страница 14: ...od NEXT 62 8 00 SET AM Day SaSu Heat Use these buttons to adjust the heat setpoint for the day time period NEXT 6 00 PM SaSu Use these buttons to adjust the start time for the evening time period Evening NEXT 78 6 00 SET Cool Use these buttons to adjust the cool setpoint for the evening time period Evening PM SaSu NEXT Weekend Programming ...

Страница 15: ...M SaSu NEXT Use these buttons to adjust the start time for the night time period Night I0 00 PM SaSu NEXT 82 SET SaSu Cool Use these buttons to adjust the cool setpoint for the night time period Night I0 00 PM NEXT 62 SET Heat Use these buttons to adjust the heat setpoint for the night time period Night I0 00 PM SaSu NEXT Weekend Programming ...

Страница 16: ...setting the time period programming you have 2 options 1 Run the time period program by sliding the Program Switch to the RUN position Or 2 Do not run the time period program The thermostat will operate as a manual heat cool thermostat Slide the Program Switch to OFF in this case ...

Страница 17: ...the clock is flashing press NEXT for 5 seconds Do not release the button until this screen appears Select YES to have the backlight always on or NO to turn off the backlight 8 seconds after a button press Use these buttons to select thermostat operation in degrees C or F If degrees C is selected two presses of the Up or Down buttons will be required to change the setpoint Adjust the program switch...

Страница 18: ...ate the housing halves by pulling the top forward until the pins release and then lift the bottom out To pull the housing apart insert a small blade screw driver into the slot and rotate 90 This will release the top housing snaps The batteries must be replaced immediately when the thermostat displays the Low Battery code fig 1 FIG 1 To Open The Thermostat SCREWDRIVER SLOTS ...

Страница 19: ...ARS pages 2 17 USE AA SIZE ALKALINE BATTERIES USE AA SIZE ALKALINE BATTERIES POSITION BATTERIES AS SHOWN ELEC GAS HP GAS IF THE THERMOSTAT IS CONNECTED TO 24V POWER THE BATTERIES MAY STILL BE INSTALLED INSTALLING THE BATTERIES WHEN SYSTEM POWERED 24VAC WILL KEEP THE CLOCK RUNNING IN THE EVENT OF LINE POWER INTERRUPTION ...

Страница 20: ...nstallation misapplication abuse improper servicing unauthorized alteration or improper operation 3 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 4 Damage as a result of floods winds fires lightning accidents corrosive environments or other conditions beyond the control of the Manufacturer 5...

Страница 21: ... example if the Morning Start Time is 6 30am then the Day Start Time MUST be programmed for any time AFTER the 6 30am Morning Start Time Also if the Day Start time is set for 10 30am then the Evening Start Time MUST be programmed for any time AFTER the 10 30am Day Start Time Finally if the Evening Start Time is set for 5 30pm then the Night Start Time MUST be programmed for any time AFTER the 5 30...

Отзывы: