1、

Overview:

 

TP150 digital LCD room thermostat is programmable for 4 time periods a day and 7 days a week. It mainly be used in 
the control of heating cable, heating film, heater, wall-mounted boiler and water valve on the collector in heating system. 
Based on the setting temperature, the testing ambient tempearture as the variable, it can automaticly control the power of 
the terminal equipment. Thus to achieve the thermostatic control of temperature and the display interface is shown as 
below: 
 

2、

Main functions:

 

1.

 

Manual mode:According to the manual setting 
temperature, the controller controls the room 
temperature. When the testing temperature is less than or 
equal to setting temperature -0.5

,the equipment starts. 

When the testing temperature is equal or greater than 
setting tempe0.5

, the equipment stops. 

2.

 

Auto mode

According to the setting temperature in 

different periods, the controller controls the room 
temperature, operation process is the same as Manual 
mode. 

3.

 

Antifreeze function (optional) : When the testing 
ambient temperature is less than or equal to 5 

, the 

controller will automaticly power on and start the 
equipment, when reaching 8 

, the system will be back to normal operation.

 

4.

 

Overheating protection function: When then the protecting temperature sensor tests the temperature is more 
than 55 

, the equipment will stop. When the temperature is less than 50 

, the system will recover to normal 

operation. 
 

3、

Operation setup:

 

 

3.1 

Operation sequence:

  

Switch on the power 

    ②

Press the “power” key for 3 seconds to open the thermostat

      ③

Setting the 

required ambient temperature (Manual setting temperature and programmable periods temperatures)

.     ④

Select 

the control mode (Manual/Auto). 

3.2 

Setup instruction

:  

Statement: When any icons on the LCD screen do not flash, it’s 
the normal state. If not, you can wait 10 seconds to let the system 
automatically default, or lightly press the “power” key circularly 
until it shows the normal state:

 

1.

 

Hold on the “power” key for 3 seconds to turn on/off. 

2.

 

Manual setting temperature: After choosing manual mode, in 
normal state, you can directly press 

  or 

  to set the 

manual temperature, after setting, press “power” key for 
your confirmation

3.

 

Control mode change: In normal state, a menu icon will 
flash after every press of the “menu” key, when the flashing icon is the one which the user wants, the user can 

Отзывы: