background image

Specifications

 Dimensions

 Dimensions for threads and double nipple:

Type

63/2100 D

63/2075 D

63/2050 D

Connector

1”   Whitworth

3/4”   Whitworth

3/4”   NPT

Perforation 

length

[mm]

1000

750

500

Double nipple length 

square tube 

100 x 100 mm

[mm]

150 

150 

-

Double nipple length 

square tube 

80 x 80 mm

[mm]

130 

130 

-

Double nipple length 

tube DN100 

(114,3 mm)

[mm]

190 

-

-

Colour 

code 

blue

green

grey

 Total length*

[mm]

1060

810

560

Tube 

diameter

[mm]

63

63

63

ID-Sleeve**

 

[mm]

64 - 66

64 - 66

64 - 66

 Perforated area

[m

2

]

0,18

0,135

0,09

*Other lengths on request.

** Exact diameter acc. to customer specification.

3/4” NPT-joint: maximal diffuser length 610 mm, diffuser will be connected to 3/4” NPT weld-on threaded nip-

ple. Double nipples for other tube dimensions on request.

1. Aeration System

This manual gives a detailed description of installation 

and operating of the tube diffuser JetFlex TD 63 /2 with 

the perforation lengths 1000 mm, 750 mm and 500 mm 

(39.4“,  29.5”, 19.7”).

2. General

Gummi-Jaeger  GmbH  Aeration  Components  delivers  aerating  systems  for  applications  in  aeration 

basins in communal and industrial waste water treatment plants.  

The aerating systems are intended for fine-bubble compressed air ventilation of activated sludge in 

biological waste water treatment.  With membranes  made of EPDM-rubber an intermittent operation 

is possible due to the long-term elasticity of the membrane material.

For applications in industrial waste water treatment plants and/or in communal plants along with more 

than 10% industry share please consult Gummi-Jaeger regarding suitability of membrane materials. 

Quality properties of materials, perforation and bubble size/uniformity are controlled and recorded 

generally. 

The aeration systems are delivered completely assembled. Gummi-Jaeger GmbH Aeration Components 

recommends a careful treatment of storage, transport and installation, to avoid  damage of the mem-

branes. 

The Gummi-Jaeger GmbH General Conditions of Sale are valid in their new version, respectively.

Содержание JetFlex TD 63/2

Страница 1: ...Jaeger Group of Companies Tube Diffuser Assembly Operating and Maintenance Instruction JUT_2007_03...

Страница 2: ...LLATION 6 7 OPERATING INSTRUCTIONS 7 7 1 START UP INSTRUCTIONS 7 7 2 STANDARD OPERATION 7 7 3 TROUBLE SHOOTING 8 7 4 MAINTENANCE AND CLEANING 9 7 4 1 MAINTENANCE 9 7 4 2 MECHANICAL CLEANING 9 7 4 3 CH...

Страница 3: ...gths 1000 mm 750 mm and 500 mm 39 4 29 5 19 7 2 General Gummi Jaeger GmbH Aeration Components delivers aerating systems for applications in aeration basins in communal and industrial waste water treat...

Страница 4: ...y for original and unharmed packaging 5 Storage of Equipment Store equipment and diffuser as well as all accessories in their original packaging in a dry and aerated room regarding to DIN 7716 Prevent...

Страница 5: ...s with a diameter of 34mm 1 34 aligning on horizontal axis with a tolerance of 0 5 mm 0 02 The use of 3 4 double nipples requires predrilled and tapped outlets with a diameter of 27 mm 1 06 aligning o...

Страница 6: ...dditional 1 2 to 3 4 turn with 2 fork wrenches contacting at the across flats DO NOT OVERTIGHT EN Adjust the across flats horizontal for both diffusers with a tolerance of 10 see sketch Now the perfor...

Страница 7: ...ard Operation At standard operation the air flow rate must be adjusted to maintain desired dissolved oxygen levels in the basin When adjusting the air flow rate the diffusers should be operated within...

Страница 8: ...ure Confirm blower operations switch on additional blowers Possible cause Check valve of drop lines closed or not open enough Procedure Inspect position of check valve Possible cause Incomplete air di...

Страница 9: ...a too sharp jet of water During phosphorus precipitation pure Al sulphate and Fe sulphate do not attack the membrane mate rial chemically However isolated strong sticking deposits can occur which can...

Страница 10: ...the membrane and adjusting their position fit stainless steel crimping clamps 9 on about 6 7 mm from the end of membrane see photo Place the crimping ear of the clamps on the upper side of the diffus...

Страница 11: ...Specifications Tube Diffuser 3 4 or 1 3 4 or 1...