background image

Jäger Umwelt-Technik GmbH & Co. KG

Kreisstrasse 24 c
30629 Hannover, Germany
Phone: 

(+49)511 898668-0

Fax:  

(+49)511 898668-99

www.jaeger-envirotech.com
[email protected] 

GummiJaeger LLC.

14300 I-25 Frontage Rd.
Longmont, CO 80504, USA 
Phone: 

+1 970 535-0554

Fax:  

+1 970 535-0945 

www.gummijaeger.com
[email protected] 

Jaeger Rubber and Plastics (Shenzhen) Ltd.

1/F, No. A13 Factory Building
Silicon Valley – Automobile Industry Park
Guanlan, Baoan, Shenzhen,  
China 518110
Phone: 

+86 755 29832412

Fax:  

+86 755 29832413

www.jaeger-shenzhen.cn
[email protected]

Specifications

JUT_2007_03

9. Recycling

Consider the local official regulations for deposit on dump or supply to scrap metal. Decisive are 

the valid laws at the time of waste disposal.

If our products were not contaminated by other materials, it does not concern a particularly 

monitored waste. In the case of contamination please ask your responsible authorities.

10. Disclaimer

This information is based on our present state of knowledge and is intended to provide general 

notes on our products and their uses. It should not therefore be construed as guaranteeing spe-

cific properties of the products described or their suitability for a particular application. US units 

are for convenience only. Any existing industrial property rights must be observed. The quality 

of our products is guaranteed under our General Conditions of Sale.

11. Reference

•   DIN 7716, Erzeugnisse aus Kautschuk und Gummi, Anforderungen an die Lagerung,  

 

    Reinigung  und Wartung, Beuth Verlag, Berlin 1982.

•   TA Luft, Technische Anleitung zur Reinhaltung der Luft, 1986.

•   DWA-M 115, Indirekteinleitung nicht häuslichen Abwassers, DWA, Hennef, 2004

•   ATV M-209, Messung der Sauerstoffzufuhr von Belüftungseinrichtungen in    

 

 

    Belebungsanlagen in Reinwasser und in belebten Schlamm, Gesellschaft zur Förderung der  

    Abwassertechnik e.V. (GFA), Hennef 1996.

•   PrEN 12255-15, Wastewater treatment plants - Part 15: Measurement of the oxygen transfer  

    in clean water in activated sludge aeration tanks, European Committee For Standardization,  

    Brussels, 1999. ANSI/ASCE 2-91, Measurement of Oxygen Transfer in Clean Water,  

 

    American Society of Cicil Engineers, New York, 1992.

Содержание JetFlex TD 63/2

Страница 1: ...Jaeger Group of Companies Tube Diffuser Assembly Operating and Maintenance Instruction JUT_2007_03...

Страница 2: ...LLATION 6 7 OPERATING INSTRUCTIONS 7 7 1 START UP INSTRUCTIONS 7 7 2 STANDARD OPERATION 7 7 3 TROUBLE SHOOTING 8 7 4 MAINTENANCE AND CLEANING 9 7 4 1 MAINTENANCE 9 7 4 2 MECHANICAL CLEANING 9 7 4 3 CH...

Страница 3: ...gths 1000 mm 750 mm and 500 mm 39 4 29 5 19 7 2 General Gummi Jaeger GmbH Aeration Components delivers aerating systems for applications in aeration basins in communal and industrial waste water treat...

Страница 4: ...y for original and unharmed packaging 5 Storage of Equipment Store equipment and diffuser as well as all accessories in their original packaging in a dry and aerated room regarding to DIN 7716 Prevent...

Страница 5: ...s with a diameter of 34mm 1 34 aligning on horizontal axis with a tolerance of 0 5 mm 0 02 The use of 3 4 double nipples requires predrilled and tapped outlets with a diameter of 27 mm 1 06 aligning o...

Страница 6: ...dditional 1 2 to 3 4 turn with 2 fork wrenches contacting at the across flats DO NOT OVERTIGHT EN Adjust the across flats horizontal for both diffusers with a tolerance of 10 see sketch Now the perfor...

Страница 7: ...ard Operation At standard operation the air flow rate must be adjusted to maintain desired dissolved oxygen levels in the basin When adjusting the air flow rate the diffusers should be operated within...

Страница 8: ...ure Confirm blower operations switch on additional blowers Possible cause Check valve of drop lines closed or not open enough Procedure Inspect position of check valve Possible cause Incomplete air di...

Страница 9: ...a too sharp jet of water During phosphorus precipitation pure Al sulphate and Fe sulphate do not attack the membrane mate rial chemically However isolated strong sticking deposits can occur which can...

Страница 10: ...the membrane and adjusting their position fit stainless steel crimping clamps 9 on about 6 7 mm from the end of membrane see photo Place the crimping ear of the clamps on the upper side of the diffus...

Страница 11: ...Specifications Tube Diffuser 3 4 or 1 3 4 or 1...

Страница 12: ...of knowledge and is intended to provide general notes on our products and their uses It should not therefore be construed as guaranteeing spe cific properties of the products described or their suita...

Отзывы: