background image

JÄGER DIREKT · OPUS Straße 1 · 64646 Heppenheim · [email protected] · www.myOPUS.eu

Installation guide

OPUS 55 SENS Temperature-humidity sensor

Battery operation Art. No. 563.043.37, 563.043.43, 563.043.51, 563.043.66; incl. 
power supply unit art. no. 563.044.37, 563.044.43, 563.044.51, 563.044.66

 

1. Product description

OPUS 55 SENS is an intelligent sensor for the detection of temperature and humi-
dity, suitable for single room control as well as for integration into common smart 
home applications. Available in four different colors, OPUS 55 SENS comple-
ments any popular 55 switch program, especially the OPUS 55 designs. 
It can be operated either with a battery or with the help of an additional power 
supply unit as part of the building installation technology. Based on the integra-
ted EnOcean radio module, the purely battery-powered OPUS 55 SENS can be 
installed in almost any conceivable mounting position and is therefore particularly 
suitable for existing buildings. 
The supplied bracket is either screwed or glued and simplifies surface mounting of 
the sensor. In connection with an external power supply, OPUS 55 SENS is con-
nected to the house installation in a flush-mounted switch box (deep), which all-
ows a permanent power supply. Optional: In combination with an external sensor, 
OPUS 55 SENS detects leakage situations and reports them immediately. The 
sensor stores and communicates a short-term occurrence of leakage for 14 days. 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.1 Specifications

Power supply

Battery: Type CR2450, 

operating time > 7 years (typ.) 

external power supply 230 V AC

Measuring ranges

Temperature: 0 °C … +50 °C, 

humidity: 0 % rh  … 100 % rh

Measuring cycle

120 seconds

Transmission cycle

2 min. at change >0.2°C or 

>5 % rH, 20 min. maximum

SIGNAL Message

every 240 minutes

Leakage (optional)

external, 2 detection zones; 

sending with state change, 

14 days history

Ambient conditions

from -10°C to +50°C, max 98 % rH, 

non-condensing

EnOcean radio

868,3 MHz ASK max. 10 mW

Protection class

IP30

1.2 Intended use

OPUS 55 SENS is used to measure room temperature and relative humidity in-
doors. In combination with qualified accessories, it is used to detect leakage in the 
environment of water installations. 
OPUS 55 SENS has been developed for domestic use and similar fixed installations. 
Prior to installation, check the suitability on the basis of the technical data and the 
operating conditions. OPUS 55 SENS must not be used in conjunction with life-sup-
porting devices or with products that may cause danger to the life or limb of people 
and animals or to property.

 
1.3 Warranty

The guarantee expires if Opus 55 Sens is not used according to its intended use 
if not qualified accessories are connected when the housing is opened or if other 
interventions are carried out on the device.

                                 

2. Installation and commissioning 

2.1 Battery operation

For initial commissioning, pull out the isolation tab 
on the back of the OPUS 55 SENS in the direction 
of the arrow and remove it. The inserted battery is 
thereby connected and the OPUS 55 SENS performs 
a restart. At this point, the sensor sends a standard-
ized teach-in telegram (UTE). Subsequently, it sends 
a measured value ten times in succession every 2 
minutes. 

The SIGNAL messages transmit both the energy status and the version of the device 
for the first time within 5 minutes after commissioning. After removing the isolation 
tab, place the separately available 1-fold frame on the bracket. Then insert the OPUS 
55 SENS into the frame and snap it into place (see Fig. 2). 

 
 

 
 

 
 
 
 
 
 
 
 

BATTERY REPLACEMENT: 

Press a tool, e.g. a commercially available screwdriver 
or a nail (not included in the scope of delivery) into the 
slot, for unlocking on the front of the OPUS 55 SENS 
and pull the device out of the frame (see Fig. 3). Re-
place the battery in the battery compartment on the 
back. Place the frame, insert the OPUS 55 SENS and 
snap it into place.
 

2.2 Mains operation via ext. power supply unit

In combination with the external power supply unit, OPUS 55 SENS is simply 
installed on a flush-mounted switch box (deep) with 230 V supply voltage. 
The power supply unit is connected to the power supply using commer-
cially available terminals according to the connection diagram (see Fig. 
4). It is important to note that the circuits are separated in accordan-
ce with the insulation regulations for protection class II. During installa-
tion, the 230 V cable must be behind the power supply unit and the con-
necting cable with 4-pin socket must be in front of the power supply unit.  
 
 
 
 
 
 
 
 
 
 
 
 
 

OPUS 55 SENS

Frame

Wall bracket/ 

Wall plate

Содержание OPUS 55 SENS

Страница 1: ...wurde zum Einsatz im Haushalt und in ähnlichen ortsfesten Installationen entwickelt Vor Installation ist die Eignung anhand der technischen Daten und den Einsatzbedingungen zu überprüfen OPUS 55 SENS darf nicht eingesetzt werden in Verbindung mit lebenserhaltenden Geräten oder mit Produk ten die zu Gefahren für Leib oder Leben von Menschen und Tieren oder zu Ge fahren für Sachwerte führen können 1...

Страница 2: ...ngebracht werden Außenwände und Zugluft von Fenstern Türen sollten ver mieden werden Es sollte gewährleistet werden dass die normale Umgebungs luft den Sensor ungehindert erreicht BEEINTRÄCHTIGUNG Die Präzision des OPUS 55 SENS wird durch Abdecken der freien Luftzirkulation und bei direktem Einfluss von Wärmequellen beeinträchtigt Hierzu zählen direkte Sonneneinstrahlung sowie die Nähe elektrische...

Страница 3: ...llations OPUS 55 SENS has been developed for domestic use and similar fixed installations Prior to installation check the suitability on the basis of the technical data and the operating conditions OPUS 55 SENS must not be used in conjunction with life sup porting devices or with products that may cause danger to the life or limb of people and animals or to property 1 3 Warranty The guarantee expi...

Страница 4: ... behind curtains etc Exterior walls and drafts from windows doors should be avoided It should be ensured that the normal ambient air reaches the sensor unhindered IMPAIRMENT The precision of the OPUS 55 SENS is impaired by covering the free air circulation and in case of direct influence of heat sources These include direct sunlight and the proximity of electrical appliances radiators heating pipe...

Страница 5: ...cteren De OPUS 55 SENS is ontwikkeld voor gebruik binnenshuis en in soortgelijke vaste installaties Vóór de installatie moet de geschiktheid worden gecontroleerd op basis van de technische gegevens en de bedrijfsomstandigheden De OPUS 55 SENS mag niet worden gebruikt in combinatie met levensondersteunende apparaten of met pro ducten die gevaar kunnen opleveren voor lijf en ledematen van mens en di...

Страница 6: ...de grond OPUS 55 SENS mag niet worden aangebracht in rekwanden achter gordijnen enz Buitenmuren en tocht van ramen deuren moeten worden vermeden Er moet voor worden gezorgd dat de normale omgevingslucht ongehinderd de sensor bereikt BENADELING De precisie van de OPUS 55 SENS wordt beïnvloed door het afdekken van de vrije luchtcirculatie en door directe invloed van warmtebronnen Dit omvat direct zo...

Отзывы: